ESI快速定位电子数据表Paxtondsctext =ESI高速达克-DNCreateDate=12-14-2004创建时间=9:18:00ModDate=1214-2004ModTime = 5: 00修订版=1.2VendCode 804销商代码VendName=Eectro传感器公司销主名prodType=0$General设备类型predTystr=Generic设备ProdCode=2ESI产品编码MajRev=1ESI校验MinRev=1speedTalker-DN$ESI产品名目录=800-001200$ESI目录数[IO_Info]默认值=0x005$COS和poll默认pollfo=0x0005$默认输出:输出1COSInfo=0x0005,$可与poll2合并$默认输出:输出2$-输入连接3,$3字节数据0,$所有位数均值0x0001,$poll连接RPM和Awars Status,$Natestrie6,$Nation路径规模20042465303,$连接路径4/101/3RPMlo输入2=1,$1字节数据4,$4使用0x0004,$COS连接“仅报警状态”,$Name字符串6,$连接路径大小20652401300,$连接路径101/1/16Low4提醒4Opent1=000字节数据0$0x0001$poll连接“不消耗数据”Opport2=000字节数据0$0x0004$COS连接“不消耗数据”马克斯Inst=19$#参数实例描述器0x09$Param自备N.V.Cfgserm=0[Params] Param1 = 0, $ Reserved (always 0) 6,"20 64 24 01 30 01", $ path size, path: 100/1/1 0x0000, $ descriptor 0xC7, $ data type UINT (vol 1, J-6.1) 2, $ data size 2 bytes "Target pulses/rev", $ name "PPR", $ units "+/- pulse pairs per target revolution", $ help string 1,256,8, $ min value, max value, default 1,1,1,0, $ mult, div, base, offset scaling 0,0,0,0, $ mult, div, base, offset links not used 0!无小数缩放Param2=0,$served6,20642401302,$路径大小:100/1/20x0044,$descripor0xC7,$数据类型UINT(vol 1,J-6.1)2,$数据规模2字节容积速度 units0RPM低于此设置实际速度 $帮助字符串16553510美分 最大值 默认1110美分$ 1 digit right of decimal place Param3 = 0, $ Reserved (always 0) 6,"20 64 24 01 30 03", $ path size, path: 100/1/3 0x0074, $ descriptor 0xC7, $ data type UINT (vol 1, J-6.1) 2, $ data size 2 bytes "Measured speed", $ name "RPM", $ units "Real-time measured target RPM", $ help string 0,65535,0, $ min value, max value, default 1,1,1,0, $ mult, div, base, offset scaling 0,0,0,0, $ mult, div, base, offset links not used 1!$ 1 digit right of decimal place Param4 = 0, $ Reserved (always 0) 6,"20 65 24 01 30 01", $ path size, path: 101/1/1 0x0044, $ descriptor 0xC7, $ data type UINT (vol 1, J-6.1) 2, $ data size 2 bytes "Alarm 1 threshold", $ name "RPM", $ units "RPM setting for Alarm 1", $ help string 1,65535,10, $ min value, max value, default 1,1,1,0, $ mult, div, base, offset scaling 0,0,0,0, $ mult, div, base, offset links not used 1!$ 1 digit right of decimal place Param5 = 0, $ Reserved (always 0) 6,"20 65 24 01 30 02", $ path size, path: 101/1/2 0x0044, $ descriptor 0xC6, $ data type USINT (vol 1, J-6.1) 1, $ data size 1 byte "Alarm 1 ON delay", $ name "sec", $ units "Time that RPM must be at alarm-level before Alarmed state", 0,250,10, $ min value, max value, default 1,1,1,0, $ mult, div, base, offset scaling 0,0,0,0, $ mult, div, base, offset links not used 1!$ 1 digit right of decimal place Param6 = 0, $ Reserved (always 0) 6,"20 65 24 01 30 03", $ path size, path: 101/1/3 0x0044, $ descriptor 0xC6, $ data type USINT (vol 1, J-6.1) 1, $ data size 1 byte "Alarm 1 ON min time", $ name "sec", $ units "Minimum time Alarm 1 stays Alarmed", 0,250,10, $ min value, max value, default 1,1,1,0, $ mult, div, base, offset scaling 0,0,0,0, $ mult, div, base, offset links not used 1!$ 1 digit right of decimal place Param7 = 0, $ Reserved (always 0) 6,"20 65 24 01 30 04", $ path size, path: 101/1/4 0x0044, $ descriptor 0xC7, $ data type UINT (vol 1, J-6.1) 2, $ data size 2 bytes "Alarm 2 threshold", $ name "RPM", $ units "RPM setting for Alarm 2", $ help string 1,65535,10, $ min value, max value, default 1,1,1,0, $ mult, div, base, offset scaling 0,0,0,0, $ mult, div, base, offset links not used 1!$ 1 digit right of decimal place Param8 = 0, $ Reserved (always 0) 6,"20 65 24 01 30 05", $ path size, path: 101/1/5 0x0044, $ descriptor 0xC6, $ data type USINT (vol 1, J-6.1) 1, $ data size 1 byte "Alarm 2 ON delay", $ name "sec", $ units "Time that RPM must be at alarm-level before Alarmed state", 0,250,10, $ min value, max value, default 1,1,1,0, $ mult, div, base, offset scaling 0,0,0,0, $ mult, div, base, offset links not used 1!$ 1 digit right of decimal place Param9 = 0, $ Reserved (always 0) 6,"20 65 24 01 30 06", $ path size, path: 101/1/6 0x0044, $ descriptor 0xC6, $ data type USINT (vol 1, J-6.1) 1, $ data size 1 byte "Alarm 2 ON min time", $ name "sec", $ units "Minimum time Alarm 2 stays Alarmed", 0,250,10, $ min value, max value, default 1,1,1,0, $ mult, div, base, offset scaling 0,0,0,0, $ mult, div, base, offset links not used 1!$ 1 digit right of decimal place Param10 = 0, $ Reserved (always 0) 6,"20 65 24 01 30 07", $ path size, path: 101/1/7 0x0044, $ descriptor 0xC7, $ data type UINT (vol 1, J-6.1) 2, $ data size 2 bytes "Alarm 3 threshold", $ name "RPM", $ units "RPM setting for Alarm 3", $ help string 1,65535,10, $ min value, max value, default 1,1,1,0, $ mult, div, base, offset scaling 0,0,0,0, $ mult, div, base, offset links not used 1!$ 1 digit right of decimal place Param11 = 0, $ Reserved (always 0) 6,"20 65 24 01 30 08", $ path size, path: 101/1/8 0x0044, $ descriptor 0xC6, $ data type USINT (vol 1, J-6.1) 1, $ data size 1 byte "Alarm 3 ON delay", $ name "sec", $ units "Time that RPM must be at alarm-level before Alarmed state", 0,250,10, $ min value, max value, default 1,1,1,0, $ mult, div, base, offset scaling 0,0,0,0, $ mult, div, base, offset links not used 1!$ 1 digit right of decimal place Param12 = 0, $ Reserved (always 0) 6,"20 65 24 01 30 09", $ path size, path: 101/1/9 0x0044, $ descriptor 0xC6, $ data type USINT (vol 1, J-6.1) 1, $ data size 1 byte "Alarm 3 ON min time", $ name "sec", $ units "Minimum time Alarm 3 stays Alarmed", 0,250,10, $ min value, max value, default 1,1,1,0, $ mult, div, base, offset scaling 0,0,0,0, $ mult, div, base, offset links not used 1!$ 1 digit right of decimal place Param13 = 0, $ Reserved (always 0) 6,"20 65 24 01 30 0A", $ path size, path: 101/1/10 0x0044, $ descriptor 0xC7, $ data type UINT (vol 1, J-6.1) 2, $ data size 2 bytes "Alarm 4 threshold", $ name "RPM", $ units "RPM setting for Alarm 4", $ help string 1,65535,10, $ min value, max value, default 1,1,1,0, $ mult, div, base, offset scaling 0,0,0,0, $ mult, div, base, offset links not used 1!$ 1 digit right of decimal place Param14 = 0, $ Reserved (always 0) 6,"20 65 24 01 30 0B", $ path size, path: 101/1/11 0x0044, $ descriptor 0xC6, $ data type USINT (vol 1, J-6.1) 1, $ data size 1 byte "Alarm 4 ON delay", $ name "sec", $ units "Time that RPM must be at alarm-level before Alarmed state", 0,250,10, $ min value, max value, default 1,1,1,0, $ mult, div, base, offset scaling 0,0,0,0, $ mult, div, base, offset links not used 1!$ 1 digit right of decimal place Param15 = 0, $ Reserved (always 0) 6,"20 65 24 01 30 0C", $ path size, path: 101/1/12 0x0044, $ descriptor 0xC6, $ data type USINT (vol 1, J-6.1) 1, $ data size 1 byte "Alarm 4 ON min time", $ name "sec", $ units "Minimum time Alarm 4 stays Alarmed", 0,250,10, $ min value, max value, default 1,1,1,0, $ mult, div, base, offset scaling 0,0,0,0, $ mult, div, base, offset links not used 1!$ 1 digit right of decimal place Param16 = 0, $ Reserved (always 0) 6,"20 65 24 01 30 0D", $ path size, path: 101/1/13 0x0044, $ descriptor 0xC6, $ data type USINT (vol 1, J-6.1) 1, $ data size 1 byte "Alarm threshold Hysteresis", $ name "%", $ units "Applied to all alarm thresholds", 0,250,10, $ min value, max value, default 1,1,1,0, $ mult, div, base, offset scaling 0,0,0,0, $ mult, div, base, offset links not used 1!$ no decimal scaling Param17 = 0, $ Reserved (always 0) 6,"20 65 24 01 30 0E", $ path size, path: 101/1/14 0x0000, $ descriptor 0xD1, $ data type (vol 1, J-6.1) 1, $ data size 1 byte "Alarm4...1 (Bit3...0) Over/Under settings", $ name "", $ units "1: Overspeed Alarm, 0: Underspeed Alarm", 0b0000000,0b00001111,0b00000000, $ min value, max value, default 1,1,1,0, $ mult, div, base, offset scaling 0,0,0,0, $ mult, div, base, offset links not used 0!$ no decimal scaling Param18 = 0, $ Reserved (always 0) 6,"20 65 24 01 30 0F", $ path size, path: 101/1/15 0x0000, $ descriptor 0xD1, $ data type (vol 1, J-6.1) 1, $ data size 1 byte "Alarm4...1 (Bit3...0) ON/OFF settings", $ name "", $ units "1: ON, 0: OFF", 0b0000000,0b00001111,0b00000000, $ min value, max value, default 1,1,1,0, $ mult, div, base, offset scaling 0,0,0,0, $ mult, div, base, offset links not used 0!$ no decimal scaling Param19 = 0, $ Reserved (always 0) 6,"20 65 24 01 30 10", $ path size, path: 101/1/16 0x0030, $ descriptor: 0xD1, $ data type (vol 1, J-6.1) 1, $ data size 1 byte "Alarm 4...1 (Bit3...0) status", $ name "", $ units "1: Alarmed, 0: Not Alarmed", 0b0000000,0b00001111,0b00000000, $ min value, max value, default 1,1,1,0, $ mult, div, base, offset scaling 0,0,0,0, $ mult, div, base, offset links not used 0!无小数缩放组1 = Speed配置,3,1,2,3Group2 = Alarm配置 16,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,193组=监听器2 3 19