Exctext=NXR-ILM08C-EITEDS文件CreateDate=08-06-2019创建时间=12:07:21ModDate=0107-2020ModTime=16:47:25修订版=1.0HomeURL=www.omron.co.jVendCode=47VendName=OMRON公司ProdType=12ProdTypeStr=通信适配器ProdCode=1699MajRev=1MinRev=1ProdName=NXR-ILM08C-EITCatalog=NXR-ILM08C-EIT图标=NXR-ILM08C-EITi第1类EtherNetIP[Params] Param1 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ Data Type Byte 2, $ Data Size in bytes "Unit Error Occurrence Status", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param2 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ Data Type Byte 2, $ Data Size in bytes "Unit Status", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param3 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ Data Type Byte 2, $ Data Size in bytes "IO Port Status", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param4 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC7, $ Data Type Byte 2, $ Data Size in bytes "Reserve1", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param5 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC7, $ Data Type Byte 2, $ Data Size in bytes "Unit/Input Power Supply Voltage", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param6 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC7, $ Data Type Byte 2, $ Data Size in bytes "Output Power Supply Voltage", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param7 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ Data Type Byte 2, $ Data Size in bytes "Port 1 Error Status", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param8 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ Data Type Byte 2, $ Data Size in bytes "Port 2 Error Status", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param9 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ Data Type Byte 2, $ Data Size in bytes "Port 3 Error Status", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param10 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ Data Type Byte 2, $ Data Size in bytes "Port 4 Error Status", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param11 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ Data Type Byte 2, $ Data Size in bytes "Port 5 Error Status", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param12 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ Data Type Byte 2, $ Data Size in bytes "Port 6 Error Status", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param13 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ Data Type Byte 2, $ Data Size in bytes "Port 7 Error Status", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param14 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ Data Type Byte 2, $ Data Size in bytes "Port 8 Error Status", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param15 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ Data Type Byte 2, $ Data Size in bytes "Pin4/Pin2 Digital Input Data", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param16 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ Data Type Byte 2, $ Data Size in bytes "Integrated IO-Link Input Data", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param17 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 1 IO-Link Input Data", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param18 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 2 IO-Link Input Data", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param19 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 3 IO-Link Input Data", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param20 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 4 IO-Link Input Data", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param21 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 5 IO-Link Input Data", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param22 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 6 IO-Link Input Data", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param23 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 7 IO-Link Input Data", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param24 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 8 IO-Link Input Data", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param25 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ Data Type Byte 2, $ Data Size in bytes "Pin4/Pin2 Digital Output Data", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param26 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 1 IO-Link Output Data", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param27 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 2 IO-Link Output Data", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param28 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 3 IO-Link Output Data", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param29 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 4 IO-Link Output Data", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param30 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 5 IO-Link Output Data", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param31 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 6 IO-Link Output Data", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param32 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 7 IO-Link Output Data", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param33 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 8 IO-Link Output Data", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places $ Param34 = $ 0, $ reserved, shall equal 0 $ ,, $ Link Path Size, Link Path $ 0x0000, $ Descriptor $ 0xC8, $ Data Type $ 4, $ Data Size in bytes $ "EtherNet/IP Port 1 FCS Error Count", $ name $ "", $ units $ "", $ help string $ 0,4294967295,0, $ min, max, default data values $ ,,,, $ mult, div, base, offset scaling $ ,,,, $ mult, div, base, offset links $ !$ decimal places $ Param35 = $ 0, $ reserved, shall equal 0 $ ,, $ Link Path Size, Link Path $ 0x0000, $ Descriptor $ 0xC8, $ Data Type $ 4, $ Data Size in bytes $ "EtherNet/IP Port 2 FCS Error Count", $ name $ "", $ units $ "", $ help string $ 0,4294967295,0, $ min, max, default data values $ ,,,, $ mult, div, base, offset scaling $ ,,,, $ mult, div, base, offset links $ !$ decimal places Param1000 = 0, $ reserved, shall equal 0 6,"20 F5 24 01 30 0A", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC1, $ Data Type Byte 1, $ Data Size in bytes "ACD Setting", $ name "", $ units "", $ help string 0,1,1, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数unm1000=0Param1001 = 0, $ reserved, shall equal 0 6,"20 F5 24 01 30 0C", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC1, $ Data Type Byte 1, $ Data Size in bytes "QuickConnnect Setting",$ name "", $ units "", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数unm1001=0$ Param1002 = $ 0, $ reserved, shall equal 0 $ 6,"20 41 24 00 30 33", $ Link Path Size, Link Path $ 0x0000, $ Descriptor $ 0xCF, $ Data Type Byte $ 6, $ Data Size in bytes $ "Event Log Present Time", $ name $ "", $ units $ "Set present time for event log when unit power on", $ help string $ 1972-01-01-00:00:00.000,2151-06-06-23:59:59.999,1972-01-01-00:00:00.000, $ min, max, default data values $ ,,,, $ mult, div, base, offset scaling $ ,,,, $ mult, div, base, offset links $ !$ decimal places Param1003 = 0, $ reserved, shall equal 0 6,"20 41 24 01 30 09", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Event Log Logged Data Configuration", $ name "", $ units "", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数unm1003=0Param1004 = 0, $ reserved, shall equal 0 7,"21 80 03 24 01 30 0C", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "NTP/SNTP Server IP Address", $ name "", $ units "", $ help string 7,15,"0.0.0.0", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1005 = 0, $ reserved, shall equal 0 7,"21 80 03 24 01 30 0D", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC7, $ Data Type Byte 2, $ Data Size in bytes "Time Zone", $ name "", $ units "", $ help string 0,42,15, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Enum1005 = 0,"(GMT -12:00) Kwajalein", 1,"(GMT -11:00) Midway Island", 2,"(GMT -10:00) USA ( Hawaii )", 3,"(GMT -09:00) USA ( Alaska )", 4,"(GMT -08:00) Canada, USA ( Pacific )", 5,"(GMT -07:00) Canada, USA ( Mountain )", 6,"(GMT -06:00) Canada, USA ( Central )", 7,"(GMT -05:00) Canada, USA ( Eastern )", 8,"(GMT -04:00) Canada ( Atlantic )", 9,"(GMT -03:30) Canada ( Newfoundland )", 10,"(GMT -03:00) Argentina", 11,"(GMT -02:00) Antarctica", 12,"(GMT -01:00) Azores", 13,"(GMT +00:00) England", 14,"(GMT +00:00) United Kingdom, Portugal", 15,"(GMT +00:00) Greenwich Mean Time ( UTC )", 16,"(GMT +01:00) France, Germany, Italy, Spain, Switzerland", 17,"(GMT +01:00) Sweden", 18,"(GMT +02:00) Bulgaria, Finland, Greece", 19,"(GMT +03:00) Russia ( Moscow, St.Petersburg )", 20,"(GMT +03:30) Iran", 21,"(GMT +04:00) Russia ( Samara, Izhevsk )", 22,"(GMT +04:30) Afghanistan", 23,"(GMT +05:00) Russia ( Yekaterinburg, Perm )", 24,"(GMT +05:30) India", 25,"(GMT +05:45) Nepal", 26,"(GMT +06:00) Russia ( Novosibirsk, Omsk )", 27,"(GMT +06:30) Myanmar", 28,"(GMT +07:00) Thailand", 29,"(GMT +07:00) Vietnam", 30,"(GMT +08:00) Australia ( Western )", 31,"(GMT +08:00) China", 32,"(GMT +08:00) Taiwan", 33,"(GMT +09:00) Japan", 34,"(GMT +09:00) Republic of Korea", 35,"(GMT +09:30) Australia ( Northern Territory ), Australia ( South )", 36,"(GMT +10:00) Australia ( New South Wales/Queensland/Victoria )", 37,"(GMT +10:30) Australia ( Lord Howe Island )", 38,"(GMT +11:00) New Caledonia", 39,"(GMT +11:30) Norfolk Island", 40,"(GMT +12:00) New Zealand", 41,"(GMT +12:45) Chatham Island", 42,"(GMT +13:00) Tonga"!Param1006 = 0, $ reserved, shall equal 0 7,"21 83 03 24 01 30 01", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "Hold Setting For Error Status", $ name "", $ units "", $ help string 0,1,1, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数unm1006=0FALSEParam1007 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 02", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 1 Device Verification Setting", $ name "", $ units "", $ help string 0,2,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 Enum1007 = 0,DibledorIDParam1008 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 03", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 1 Backup/Restore Setting", $ name "", $ units "", $ help string 0,2,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 Enum1008=0,不执行,1,backup2Param1009 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 04", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 1 Fault/Idle Action", $ name "", $ units "", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 Enum1009=0,Frail:lear,Idle:learParam1011 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 06", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 1 Pin 4 Input Filter Value Setting", $ name "", $ units "", $ help string 0,11,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Enum1011 = 0,"No Filter", 1,"0.25ms", 2,"0.5ms", 3,"1ms", 4,"2ms", 5,"4ms", 6,"8ms", 7,"16ms", 8,"32ms", 9,"64ms", 10,"128ms", 11,"256ms"!Param1012 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 07", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 1 Pin 2 Input Filter Value Setting", $ name "", $ units "", $ help string 0,11,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Enum1012 = 0,"No Filter", 1,"0.25ms", 2,"0.5ms", 3,"1ms", 4,"2ms", 5,"4ms", 6,"8ms", 7,"16ms", 8,"32ms", 9,"64ms", 10,"128ms", 11,"256ms"!Param1013 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 08", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 1 Configuration Data /Device ID", $ name "", $ units "", $ help string 0,16777215,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1014 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 09", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 1 Configuration Data /Vendor ID", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1015 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 0A", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 1 Configuration Data /IO-Link Revision", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1016 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 0B", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 1 Configuration Data /Communication Delay Time", $ name "", $ units "", $ help string 0,191,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1017 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 0C", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 1 Configuration Data /Process Data In Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1018 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 0D", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 1 Configuration Data /Process Data Out Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1019 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 0E", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 1 Pin 4 Communications Mode Setting", $ name "", $ units "", $ help string 0,3,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 Enum1019=0,Diblelity,1,SIO-DI模式,2,SIO-DO模式,3,IO-Link模式Param1020 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 0F", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 1 Pin 2 Communications Mode Setting", $ name "", $ units "", $ help string 0,2,1, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 Enum1020=0,DiblelityParam1021 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 10", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 1 Configuration Data /Serial Number", $ name "", $ units "", $ help string 0,16,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1022 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 1D", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Offset Setting of Port 1 IO-Link Input Data Collection Port", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1023 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 11", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 1 Information Area /Device ID", $ name "", $ units "", $ help string 0,16777215,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1024 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 12", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 1 Information Area /Vendor ID", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1025 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 13", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 1 Information Area /IO-Link Revision", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1026 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 14", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 1 Information Area /Cycle Time", $ name "", $ units "", $ help string 0,191,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1027 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 15", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 1 Information Area /Process Data In Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1028 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 16", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 1 Information Area /Process Data Out Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1029 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 17", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 1 Information Area /Serial Number", $ name "", $ units "", $ help string 0,16,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1030 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 18", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 1 Vendor Name of the Last Connected IO-Link Device", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1031 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 19", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 1 Product Name of the Last Connected IO-Link Device", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1032 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 1A", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 1 Information Area /Vendor Name", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1033 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 1B", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 1 Information Area /Product Name", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1034 = 0, $ reserved, shall equal 0 7,"21 81 03 24 01 30 1C", $ Link Path Size, Link Path 0x0030, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 1 Lost Frames", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1035 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 02", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 2 Device Verification Setting", $ name "", $ units "", $ help string 0,2,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 Enum1035 = 0,DibledorIDParam1036 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 03", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 2 Backup/Restore Setting", $ name "", $ units "", $ help string 0,2,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数unm1036=0Param1037 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 04", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 2 Fault/Idle Action", $ name "", $ units "", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 Enum1037=0,Fault:lear,Idle:learParam1039 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 06", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 2 Pin 4 Input Filter Value Setting", $ name "", $ units "", $ help string 0,11,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Enum1039 = 0,"No Filter", 1,"0.25ms", 2,"0.5ms", 3,"1ms", 4,"2ms", 5,"4ms", 6,"8ms", 7,"16ms", 8,"32ms", 9,"64ms", 10,"128ms", 11,"256ms"!Param1040 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 07", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 2 Pin 2 Input Filter Value Setting", $ name "", $ units "", $ help string 0,11,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Enum1040 = 0,"No Filter", 1,"0.25ms", 2,"0.5ms", 3,"1ms", 4,"2ms", 5,"4ms", 6,"8ms", 7,"16ms", 8,"32ms", 9,"64ms", 10,"128ms", 11,"256ms"!Param1041 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 08", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 2 Configuration Data /Device ID", $ name "", $ units "", $ help string 0,16777215,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1042 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 09", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 2 Configuration Data /Vendor ID", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1043 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 0A", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 2 Configuration Data /IO-Link Revision", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1044 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 0B", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 2 Configuration Data /Communication Delay Time", $ name "", $ units "", $ help string 0,191,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1045 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 0C", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 2 Configuration Data /Process Data In Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1046 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 0D", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 2 Configuration Data /Process Data Out Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1047 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 0E", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 2 Pin 4 Communications Mode Setting", $ name "", $ units "", $ help string 0,3,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 Enum1047=0,Diblelity,1,SIO(DI)模式,2,SIO(DO)模式,3,IO-Link模式Param1048 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 0F", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 2 Pin 2 Communications Mode Setting", $ name "", $ units "", $ help string 0,2,1, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数enum1048=0dableParam1049 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 10", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 2 Configuration Data /Serial Number", $ name "", $ units "", $ help string 0,16,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1050 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 1D", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Offset Setting of Port 2 IO-Link Input Data Collection Port", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1051 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 11", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 2 Information Area /Device ID", $ name "", $ units "", $ help string 0,16777215,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1052 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 12", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 2 Information Area /Vendor ID", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1053 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 13", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 2 Information Area /IO-Link Revision", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1054 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 14", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 2 Information Area /Cycle Time", $ name "", $ units "", $ help string 0,191,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1055 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 15", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 2 Information Area /Process Data In Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1056 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 16", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 2 Information Area /Process Data Out Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1057 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 17", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 2 Information Area /Serial Number", $ name "", $ units "", $ help string 0,16,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1058 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 18", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 2 Vendor Name of the Last Connected IO-Link Device", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1059 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 19", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 2 Product Name of the Last Connected IO-Link Device", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1060 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 1A", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 2 Information Area /Vendor Name", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1061 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 1B", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 2 Information Area /Product Name", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1062 = 0, $ reserved, shall equal 0 7,"21 81 03 24 02 30 1C", $ Link Path Size, Link Path 0x0030, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 2 Lost Frames", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1063 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 02", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 3 Device Verification Setting", $ name "", $ units "", $ help string 0,2,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 Enum1063 = 0,DibledorID,1,VendorID,OptedID和IO-Link校验2,VendorID,EptedID,IO-Link校验Param1064 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 03", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 3 Backup/Restore Setting", $ name "", $ units "", $ help string 0,2,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数unm1064=0Param1065 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 04", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 3 Fault/Idle Action", $ name "", $ units "", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数unum1065=0florParam1067 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 06", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 3 Pin 4 Input Filter Value Setting", $ name "", $ units "", $ help string 0,11,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Enum1067 = 0,"No Filter", 1,"0.25ms", 2,"0.5ms", 3,"1ms", 4,"2ms", 5,"4ms", 6,"8ms", 7,"16ms", 8,"32ms", 9,"64ms", 10,"128ms", 11,"256ms"!Param1068 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 07", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 3 Pin 2 Input Filter Value Setting", $ name "", $ units "", $ help string 0,11,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Enum1068 = 0,"No Filter", 1,"0.25ms", 2,"0.5ms", 3,"1ms", 4,"2ms", 5,"4ms", 6,"8ms", 7,"16ms", 8,"32ms", 9,"64ms", 10,"128ms", 11,"256ms"!Param1069 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 08", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 3 Configuration Data /Device ID", $ name "", $ units "", $ help string 0,16777215,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1070 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 09", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 3 Configuration Data /Vendor ID", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1071 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 0A", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 3 Configuration Data /IO-Link Revision", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1072 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 0B", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 3 Configuration Data /Communication Delay Time", $ name "", $ units "", $ help string 0,191,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1073 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 0C", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 3 Configuration Data /Process Data In Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1074 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 0D", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 3 Configuration Data /Process Data Out Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1075 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 0E", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 3 Pin 4 Communications Mode Setting", $ name "", $ units "", $ help string 0,3,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 Enum1075=0,Diblelity,1,SIO(DI)模式,2,SIO(DO)模式,3,IO-Link模式Param1076 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 0F", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 3 Pin 2 Communications Mode Setting", $ name "", $ units "", $ help string 0,2,1, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数unm1076=0dableParam1077 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 10", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 3 Configuration Data /Serial Number", $ name "", $ units "", $ help string 0,16,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1078 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 1D", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Offset Setting of Port 3 IO-Link Input Data Collection Port", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1079 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 11", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 3 Information Area /Device ID", $ name "", $ units "", $ help string 0,16777215,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1080 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 12", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 3 Information Area /Vendor ID", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1081 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 13", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 3 Information Area /IO-Link Revision", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1082 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 14", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 3 Information Area /Cycle Time", $ name "", $ units "", $ help string 0,191,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1083 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 15", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 3 Information Area /Process Data In Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1084 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 16", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 3 Information Area /Process Data Out Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1085 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 17", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 3 Information Area /Serial Number", $ name "", $ units "", $ help string 0,16,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1086 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 18", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 3 Vendor Name of the Last Connected IO-Link Device", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1087 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 19", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 3 Product Name of the Last Connected IO-Link Device", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1088 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 1A", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 3 Information Area /Vendor Name", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1089 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 1B", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 3 Information Area /Product Name", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1090 = 0, $ reserved, shall equal 0 7,"21 81 03 24 03 30 1C", $ Link Path Size, Link Path 0x0030, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 3 Lost Frames", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1091 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 02", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 4 Device Verification Setting", $ name "", $ units "", $ help string 0,2,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 Enum1091 = 0,DibledorIDParam1092 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 03", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 4 Backup/Restore Setting", $ name "", $ units "", $ help string 0,2,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数unum1092=0Param1093 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 04", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 4 Fault/Idle Action", $ name "", $ units "", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 Enum1093=0,Fault:lear,Idle:learParam1095 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 06", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 4 Pin 4 Input Filter Value Setting", $ name "", $ units "", $ help string 0,11,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Enum1095 = 0,"No Filter", 1,"0.25ms", 2,"0.5ms", 3,"1ms", 4,"2ms", 5,"4ms", 6,"8ms", 7,"16ms", 8,"32ms", 9,"64ms", 10,"128ms", 11,"256ms"!Param1096 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 07", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 4 Pin 2 Input Filter Value Setting", $ name "", $ units "", $ help string 0,11,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Enum1096 = 0,"No Filter", 1,"0.25ms", 2,"0.5ms", 3,"1ms", 4,"2ms", 5,"4ms", 6,"8ms", 7,"16ms", 8,"32ms", 9,"64ms", 10,"128ms", 11,"256ms"!Param1097 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 08", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 4 Configuration Data /Device ID", $ name "", $ units "", $ help string 0,16777215,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1098 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 09", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 4 Configuration Data /Vendor ID", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1099 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 0A", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 4 Configuration Data /IO-Link Revision", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1100 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 0B", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 4 Configuration Data /Communication Delay Time", $ name "", $ units "", $ help string 0,191,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1111 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 0C", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 4 Configuration Data /Process Data In Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1112 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 0D", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 4 Configuration Data /Process Data Out Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1113 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 0E", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 4 Pin 4 Communications Mode Setting", $ name "", $ units "", $ help string 0,3,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 Enum1113=0,Diblelity,1,SIODI模式,2,SIODO模式3,IO链路模式Param1114 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 0F", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 4 Pin 2 Communications Mode Setting", $ name "", $ units "", $ help string 0,2,1, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数Enum1114=0DParam1115 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 10", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 4 Configuration Data /Serial Number", $ name "", $ units "", $ help string 0,16,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1116 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 1D", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Offset Setting of Port 4 IO-Link Input Data Collection Port", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1117 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 11", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 4 Information Area /Device ID", $ name "", $ units "", $ help string 0,16777215,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1118 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 12", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 4 Information Area /Vendor ID", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1119 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 13", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 4 Information Area /IO-Link Revision", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1120 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 14", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 4 Information Area /Cycle Time", $ name "", $ units "", $ help string 0,191,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1121 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 15", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 4 Information Area /Process Data In Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1122 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 16", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 4 Information Area /Process Data Out Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1123 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 17", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 4 Information Area /Serial Number", $ name "", $ units "", $ help string 0,16,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1124 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 18", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 4 Vendor Name of the Last Connected IO-Link Device", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1125 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 19", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 4 Product Name of the Last Connected IO-Link Device", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1126 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 1A", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 4 Information Area /Vendor Name", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1127 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 1B", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 4 Information Area /Product Name", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1128 = 0, $ reserved, shall equal 0 7,"21 81 03 24 04 30 1C", $ Link Path Size, Link Path 0x0030, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 4 Lost Frames", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1129 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 02", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 5 Device Verification Setting", $ name "", $ units "", $ help string 0,2,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 Enum1129 = 0,DibledorIDParam1130 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 03", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 5 Backup/Restore Setting", $ name "", $ units "", $ help string 0,2,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数unum1130=0Param1131 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 04", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 5 Fault/Idle Action", $ name "", $ units "", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 Enum1131=0,Fault:lear,Idle:learParam1133 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 06", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 5 Pin 4 Input Filter Value Setting", $ name "", $ units "", $ help string 0,11,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Enum1133 = 0,"No Filter", 1,"0.25ms", 2,"0.5ms", 3,"1ms", 4,"2ms", 5,"4ms", 6,"8ms", 7,"16ms", 8,"32ms", 9,"64ms", 10,"128ms", 11,"256ms"!Param1134 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 07", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 5 Pin 2 Input Filter Value Setting", $ name "", $ units "", $ help string 0,11,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Enum1134 = 0,"No Filter", 1,"0.25ms", 2,"0.5ms", 3,"1ms", 4,"2ms", 5,"4ms", 6,"8ms", 7,"16ms", 8,"32ms", 9,"64ms", 10,"128ms", 11,"256ms"!Param1135 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 08", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 5 Configuration Data /Device ID", $ name "", $ units "", $ help string 0,16777215,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1136 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 09", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 5 Configuration Data /Vendor ID", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1137 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 0A", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 5 Configuration Data /IO-Link Revision", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1138 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 0B", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 5 Configuration Data /Communication Delay Time", $ name "", $ units "", $ help string 0,191,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1139 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 0C", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 5 Configuration Data /Process Data In Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1140 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 0D", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 5 Configuration Data /Process Data Out Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1141 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 0E", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 5 Pin 4 Communications Mode Setting", $ name "", $ units "", $ help string 0,3,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 Enum1141=0,Diblelity,1,SIO-DI模式,2,SIO-DO模式,3,IO-Link模式Param1142 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 0F", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 5 Pin 2 Communications Mode Setting", $ name "", $ units "", $ help string 0,2,1, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数unm1142=0dableParam1143 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 10", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 5 Configuration Data /Serial Number", $ name "", $ units "", $ help string 0,16,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1144 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 1D", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Offset Setting of Port 5 IO-Link Input Data Collection Port", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1145 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 11", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 5 Information Area /Device ID", $ name "", $ units "", $ help string 0,16777215,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1146 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 12", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 5 Information Area /Vendor ID", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1147 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 13", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 5 Information Area /IO-Link Revision", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1148 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 14", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 5 Information Area /Cycle Time", $ name "", $ units "", $ help string 0,191,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1149 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 15", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 5 Information Area /Process Data In Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1150 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 16", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 5 Information Area /Process Data Out Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1151 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 17", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 5 Information Area /Serial Number", $ name "", $ units "", $ help string 0,16,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1152 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 18", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 5 Vendor Name of the Last Connected IO-Link Device", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1153 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 19", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 5 Product Name of the Last Connected IO-Link Device", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1154 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 1A", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 5 Information Area /Vendor Name", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1155 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 1B", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 5 Information Area /Product Name", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1156 = 0, $ reserved, shall equal 0 7,"21 81 03 24 05 30 1C", $ Link Path Size, Link Path 0x0030, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 5 Lost Frames", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1157 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 02", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 6 Device Verification Setting", $ name "", $ units "", $ help string 0,2,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 Enum1157 = 0,DibledorID,1,VendorID,OptedID和IO-Link校验2,VendorID,EptedID,IO-Link校验Param1158 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 03", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 6 Backup/Restore Setting", $ name "", $ units "", $ help string 0,2,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数unum158=0noneParam1159 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 04", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 6 Fault/Idle Action", $ name "", $ units "", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 Enum1159=0,Fault:lear,Idle:learParam1161 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 06", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 6 Pin 4 Input Filter Value Setting", $ name "", $ units "", $ help string 0,11,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Enum1161 = 0,"No Filter", 1,"0.25ms", 2,"0.5ms", 3,"1ms", 4,"2ms", 5,"4ms", 6,"8ms", 7,"16ms", 8,"32ms", 9,"64ms", 10,"128ms", 11,"256ms"!Param1162 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 07", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 6 Pin 2 Input Filter Value Setting", $ name "", $ units "", $ help string 0,11,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Enum1162 = 0,"No Filter", 1,"0.25ms", 2,"0.5ms", 3,"1ms", 4,"2ms", 5,"4ms", 6,"8ms", 7,"16ms", 8,"32ms", 9,"64ms", 10,"128ms", 11,"256ms"!Param1163 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 08", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 6 Configuration Data /Device ID", $ name "", $ units "", $ help string 0,16777215,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1164 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 09", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 6 Configuration Data /Vendor ID", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1165 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 0A", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 6 Configuration Data /IO-Link Revision", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1166 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 0B", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 6 Configuration Data /Communication Delay Time", $ name "", $ units "", $ help string 0,191,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1167 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 0C", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 6 Configuration Data /Process Data In Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1168 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 0D", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 6 Configuration Data /Process Data Out Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1169 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 0E", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 6 Pin 4 Communications Mode Setting", $ name "", $ units "", $ help string 0,3,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !元小数位数Enum1169=0,Diblelective,1,SIO-DI模式2,SIO-DO模式3,IO-Link模式3Param1170 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 0F", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 6 Pin 2 Communications Mode Setting", $ name "", $ units "", $ help string 0,2,1, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数unm1170=0dableParam1171 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 10", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 6 Configuration Data /Serial Number", $ name "", $ units "", $ help string 0,16,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1172 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 1D", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Offset Setting of Port 6 IO-Link Input Data Collection Port", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1173 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 11", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 6 Information Area /Device ID", $ name "", $ units "", $ help string 0,16777215,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1174 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 12", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 6 Information Area /Vendor ID", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1175 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 13", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 6 Information Area /IO-Link Revision", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1176 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 14", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 6 Information Area /Cycle Time", $ name "", $ units "", $ help string 0,191,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1177 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 15", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 6 Information Area /Process Data In Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1178 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 16", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 6 Information Area /Process Data Out Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1179 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 17", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 6 Information Area /Serial Number", $ name "", $ units "", $ help string 0,16,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1180 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 18", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 6 Vendor Name of the Last Connected IO-Link Device", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1181 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 19", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 6 Product Name of the Last Connected IO-Link Device", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1182 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 1A", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 6 Information Area /Vendor Name", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1183 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 1B", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 6 Information Area /Product Name", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1184 = 0, $ reserved, shall equal 0 7,"21 81 03 24 06 30 1C", $ Link Path Size, Link Path 0x0030, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 6 Lost Frames", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1185 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 02", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 7 Device Verification Setting", $ name "", $ units "", $ help string 0,2,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !enum1185=0,DibledorID,1,VendorID,OptedID和IO-Link校验2,VendorID,EptedID,IO-Link校验Param1186 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 03", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 7 Backup/Restore Setting", $ name "", $ units "", $ help string 0,2,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数Enum1186=0,不执行,1,backup2Param1187 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 04", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 7 Fault/Idle Action", $ name "", $ units "", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 Enum1187 =0,Fault:lear,Idle:learParam1189 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 06", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 7 Pin 4 Input Filter Value Setting", $ name "", $ units "", $ help string 0,11,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Enum1189 = 0,"No Filter", 1,"0.25ms", 2,"0.5ms", 3,"1ms", 4,"2ms", 5,"4ms", 6,"8ms", 7,"16ms", 8,"32ms", 9,"64ms", 10,"128ms", 11,"256ms"!Param1190 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 07", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 7 Pin 2 Input Filter Value Setting", $ name "", $ units "", $ help string 0,11,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Enum1190 = 0,"No Filter", 1,"0.25ms", 2,"0.5ms", 3,"1ms", 4,"2ms", 5,"4ms", 6,"8ms", 7,"16ms", 8,"32ms", 9,"64ms", 10,"128ms", 11,"256ms"!Param1191 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 08", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 7 Configuration Data /Device ID", $ name "", $ units "", $ help string 0,16777215,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1192 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 09", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 7 Configuration Data /Vendor ID", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1193 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 0A", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 7 Configuration Data /IO-Link Revision", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1194 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 0B", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 7 Configuration Data /Communication Delay Time", $ name "", $ units "", $ help string 0,191,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1195 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 0C", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 7 Configuration Data /Process Data In Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1196 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 0D", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 7 Configuration Data /Process Data Out Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1197 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 0E", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 7 Pin 4 Communications Mode Setting", $ name "", $ units "", $ help string 0,3,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 Enum1197=0,Diblelity,1,SIO(DI)模式,2,SIO(DO)模式,3,IO-Link模式Param1198 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 0F", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 7 Pin 2 Communications Mode Setting", $ name "", $ units "", $ help string 0,2,1, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 Enum1198=0,Diblelity,1,SIO-DI模式,2,SIO-DO模式Param1199 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 10", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 7 Configuration Data /Serial Number", $ name "", $ units "", $ help string 0,16,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1200 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 1D", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Offset Setting of Port 7 IO-Link Input Data Collection Port", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1201 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 11", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 7 Information Area /Device ID", $ name "", $ units "", $ help string 0,16777215,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1202 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 12", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 7 Information Area /Vendor ID", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1203 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 13", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 7 Information Area /IO-Link Revision", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1204 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 14", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 7 Information Area /Cycle Time", $ name "", $ units "", $ help string 0,191,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1205 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 15", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 7 Information Area /Process Data In Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1206 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 16", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 7 Information Area /Process Data Out Length", $ name "", $ units "IO-Link Port7 Actual Process Data Output Size", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1207 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 17", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 7 Information Area /Serial Number", $ name "", $ units "", $ help string 0,16,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1208 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 18", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 7 Vendor Name of the Last Connected IO-Link Device", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1209 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 19", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 7 Product Name of the Last Connected IO-Link Device", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1210 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 1A", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 7 Information Area /Vendor Name", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1211 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 1B", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 7 Information Area /Product Name", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1212 = 0, $ reserved, shall equal 0 7,"21 81 03 24 07 30 1C", $ Link Path Size, Link Path 0x0030, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 7 Lost Frames", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1213 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 02", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 8 Device Verification Setting", $ name "", $ units "", $ help string 0,2,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 Enum1213 = 0,DibledorIDParam1214 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 03", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 8 Backup/Restore Setting", $ name "", $ units "", $ help string 0,2,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数unm1214=0Param1215 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 04", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 8 Fault/Idle Action", $ name "", $ units "", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 Enum1215 =0,Fault:lear,Idle:learParam1217 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 06", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 8 Pin 4 Input Filter Value Setting", $ name "", $ units "", $ help string 0,11,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Enum1217 = 0,"No Filter", 1,"0.25ms", 2,"0.5ms", 3,"1ms", 4,"2ms", 5,"4ms", 6,"8ms", 7,"16ms", 8,"32ms", 9,"64ms", 10,"128ms", 11,"256ms"!Param1218 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 07", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 8 Pin 2 Input Filter Value Setting", $ name "", $ units "", $ help string 0,11,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Enum1218 = 0,"No Filter", 1,"0.25ms", 2,"0.5ms", 3,"1ms", 4,"2ms", 5,"4ms", 6,"8ms", 7,"16ms", 8,"32ms", 9,"64ms", 10,"128ms", 11,"256ms"!Param1219 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 08", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 8 Configuration Data /Device ID", $ name "", $ units "", $ help string 0,16777215,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1220 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 09", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 8 Configuration Data /Vendor ID", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1221 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 0A", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 8 Configuration Data /IO-Link Revision", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1222 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 0B", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 8 Configuration Data /Communication Delay Time", $ name "", $ units "", $ help string 0,191,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1223 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 0C", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 8 Configuration Data /Process Data In Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1224 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 0D", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 8 Configuration Data /Process Data Out Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1225 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 0E", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 8 Pin 4 Communications Mode Setting", $ name "", $ units "", $ help string 0,3,3, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 Enum1225=0,Diblelity,1,SIO(DI)模式,2,SIO(DO)模式,3,IO-Link模式Param1226 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 0F", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 8 Pin 2 Communications Mode Setting", $ name "", $ units "", $ help string 0,2,1, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数unm1226=0dableParam1227 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 10", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 8 Configuration Data /Serial Number", $ name "", $ units "", $ help string 0,16,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1228 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 1D", $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Offset Setting of Port 8 IO-Link Input Data Collection Port", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1229 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 11", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 8 Information Area /Device ID", $ name "", $ units "", $ help string 0,16777215,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1230 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 12", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "Port 8 Information Area /Vendor ID", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1231 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 13", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 8 Information Area /IO-Link Revision", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1232 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 14", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 8 Information Area /Cycle Time", $ name "", $ units "", $ help string 0,191,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1233 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 15", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 8 Information Area /Process Data In Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1234 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 16", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 8 Information Area /Process Data Out Length", $ name "", $ units "", $ help string 0,32,2, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1235 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 17", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 8 Information Area /Serial Number", $ name "", $ units "", $ help string 0,16,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1236 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 18", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 8 Vendor Name of the Last Connected IO-Link Device", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1237 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 19", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 8 Product Name of the Last Connected IO-Link Device", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1238 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 1A", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 8 Information Area /Vendor Name", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1239 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 1B", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xDA, $ Data Type Byte 1, $ Data Size in bytes "Port 8 Information Area /Product Name", $ name "", $ units "", $ help string 0,64,"", $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param1240 = 0, $ reserved, shall equal 0 7,"21 81 03 24 08 30 1C", $ Link Path Size, Link Path 0x0030, $ Descriptor 0xC6, $ Data Type Byte 1, $ Data Size in bytes "Port 8 Lost Frames", $ name "", $ units "", $ help string 0,255,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param2000 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0200, $ Descriptor 0xC8, $ Data Type Byte 4, $ Data Size in bytes "RPI", $ name "", $ units "RPI value", $ help string 1000,1000000000,10000, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param3000 = 0, $ reserved, shall equal 0 7,"21 80 03 24 01 30 05", $ Link Path Size, Link Path 0x0034, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Unit/Input Power Supply Voltage ", $ name "V", $ units "", $ help string ,,0, $ min, max, default data values 1,10,1,0, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links 1!$ decimal places Param3001 = 0, $ reserved, shall equal 0 7,"21 80 03 24 01 30 06", $ Link Path Size, Link Path 0x0034, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Maximum Unit/Input Power Supply Voltage ", $ name "V", $ units "", $ help string ,,0, $ min, max, default data values 1,10,1,0, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links 1!$ decimal places Param3002 = 0, $ reserved, shall equal 0 7,"21 80 03 24 01 30 07", $ Link Path Size, Link Path 0x0034, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Minimum Unit/Iutput Power Supply Voltage ", $ name "V", $ units "", $ help string ,,0, $ min, max, default data values 1,10,1,0, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links 1!$ decimal places Param3003 = 0, $ reserved, shall equal 0 7,"21 80 03 24 01 30 08", $ Link Path Size, Link Path 0x0034, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Output Power Supply Voltage ", $ name "V", $ units "", $ help string ,,0, $ min, max, default data values 1,10,1,0, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links 1!$ decimal places Param3004 = 0, $ reserved, shall equal 0 7,"21 80 03 24 01 30 09", $ Link Path Size, Link Path 0x0034, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Maximum Output Power Supply Voltage ", $ name "V", $ units "", $ help string ,,0, $ min, max, default data values 1,10,1,0, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links 1!$ decimal places Param3005 = 0, $ reserved, shall equal 0 7,"21 80 03 24 01 30 0A", $ Link Path Size, Link Path 0x0034, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Minimum Output Power Supply Voltage", $ name "V", $ units "", $ help string ,,0, $ min, max, default data values 1,10,1,0, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links 1!$ decimal places Param3006 = 0, $ reserved, shall equal 0 7,"21 80 03 24 01 30 0B", $ Link Path Size, Link Path 0x0030, $ Descriptor 0xC8, $ Data Type 4, $ Data Size in bytes "Total Power-ON Time", $ name "h", $ units "", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param3007 = 0, $ reserved, shall equal 0 7,"21 82 03 24 01 30 01", $ Link Path Size, Link Path 0x0030, $ Descriptor 0xC8, $ Data Type 4, $ Data Size in bytes "EtherNet/IP Port 1 Link Down Count", $ name "", $ units "", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param3008 = 0, $ reserved, shall equal 0 7,"21 82 03 24 02 30 01", $ Link Path Size, Link Path 0x0030, $ Descriptor 0xC8, $ Data Type 4, $ Data Size in bytes "EtherNet/IP Port 2 Link Down Count", $ name "", $ units "", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !小数位数 第1组 = unit配置 6Group2 = “IO端口1配置”,26,10078910111013101410161017,101810991020,102110231025,1026102710271028102910303组 = IP2配置26,1035,1036,1037,1039,1040,1041,1042,1043,1044,1045,1046,1047,1048,1049,1050,1051,1052,1053,1054,1055,1056,1057,1058,1059,1060,1061Group4=IO端口3配置26 063106410651067106810691070107110721077310775107610777878710791080108108310885108871088889Group5 = IP4配置26,1091,1092,1093,1095,1096,1097,1099,1100,111111,1112,1113,1114,1115111611Group6 = IP港5配置26112911301113131411361113141414141414141414141414141414141414141414141414141414141414141114141414141114141114141114117组 = IP港6配置261157115811691161116121161416161616171168116911771117211738组 = IP港口7配置261185118611871189119011991199119911991199119611971211Group9=IO港8配置26121312151217121812191228122312241225122612261212Object_Name=ActiveObjectiveObject_Class_Code=0x04Assem1 = "Input IO-Link 2 Bytes", "20 04 24 6E 30 03", 46, 0x0000, ,, 16,Param1, 16,Param2, 16,Param3, 16,Param5, 16,Param6, 16,Param7, 16,Param8, 16,Param9, 16,Param10, 16,Param11, 16,Param12, 16,Param13, 16,Param14, 16,Param15, 16,Param16, 16,Param17, 16,Param18, 16,Param19, 16,Param20, 16,Param21, 16,Param22, 16,Param23, 16,Param24!Assem2 = "Output IO-Link 2 Bytes", "20 04 24 84 30 03", 18, 0x0000, ,, 16,Param25, 16,Param26, 16,Param27, 16,Param28, 16,Param29, 16,Param30, 16,Param31, 16,Param32, 16,Param33!Assem3 = "Input IO-Link 8 Bytes", "20 04 24 6F 30 03", 94, 0x0000, ,, 16,Param1, 16,Param2, 16,Param3, 16,Param5, 16,Param6, 16,Param7, 16,Param8, 16,Param9, 16,Param10, 16,Param11, 16,Param12, 16,Param13, 16,Param14, 16,Param15, 16,Param16, 64,Param17, 64,Param18, 64,Param19, 64,Param20, 64,Param21, 64,Param22, 64,Param23, 64,Param24!Assem4 = "Output IO-Link 8 Bytes", "20 04 24 85 30 03", 66, 0x0000, ,, 16,Param25, 64,Param26, 64,Param27, 64,Param28, 64,Param29, 64,Param30, 64,Param31, 64,Param32, 64,Param33!Assem5 = "Input IO-Link 32 Bytes", "20 04 24 70 30 03", 286, 0x0000, ,, 16,Param1, 16,Param2, 16,Param3, 16,Param5, 16,Param6, 16,Param7, 16,Param8, 16,Param9, 16,Param10, 16,Param11, 16,Param12, 16,Param13, 16,Param14, 16,Param15, 16,Param16, 256,Param17, 256,Param18, 256,Param19, 256,Param20, 256,Param21, 256,Param22, 256,Param23, 256,Param24!Assem6 = "Output IO-Link 32 Bytes", "20 04 24 86 30 03", 258, 0x0000, ,, 16,Param25, 256,Param26, 256,Param27, 256,Param28, 256,Param29, 256,Param30, 256,Param31, 256,Param32, 256,Param33!Assem7 = "Input Digital Input", "20 04 24 7E 30 03", 30, 0x0000, ,, 16,Param1, 16,Param2, 16,Param3, 16,Param5, 16,Param6, 16,Param7, 16,Param8, 16,Param9, 16,Param10, 16,Param11, 16,Param12, 16,Param13, 16,Param14, 16,Param15, 16,Param16!Assem8 = "Output Digital Ouput", "20 04 24 94 30 03", 2, 0x0000, ,, 16,Param25!Object_Name表示连接管理对象Object_Class_Code=0x06Connection1 = 0x04010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = application type: listen-only $ 25 = application type: input-only $ 26 = application type: exclusive-owner $ 27 = application type: redundant-owner $ 28-30 = reserved $ 31 = Direction: Client = 0 / Server = 1 0x44640405, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved ,2,Assem8, $ O->T RPI, size, format ,30,Assem7, $ T->O RPI, size, format ,, $ proxy config size, format ,, $ target config size, format "EO Digital I/O with Status", $ Connection Name "Exclusive Owner Connection of Digital I/O with Status", $ help string "20 04 24 01 2C 94 2C 7E"!$ Path Connection2 = 0x04010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = application type: listen-only $ 25 = application type: input-only $ 26 = application type: exclusive-owner $ 27 = application type: redundant-owner $ 28-30 = reserved $ 31 = Direction: Client = 0 / Server = 1 0x44640405, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved ,18,Assem2, $ O->T RPI, size, format ,46,Assem1, $ T->O RPI, size, format ,, $ proxy config size, format ,, $ target config size, format "EO Digital I/O, IO-Link 2 byte with Status", $ Connection Name "Exclusive Owner Connection Of Digital I/O, IO-Link 2 byte with Status", $ help string "20 04 24 01 2C 84 2C 6E"!$ Path Connection3 = 0x04010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = application type: listen-only $ 25 = application type: input-only $ 26 = application type: exclusive-owner $ 27 = application type: redundant-owner $ 28-30 = reserved $ 31 = Direction: Client = 0 / Server = 1 0x44640405, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved ,66,Assem4, $ O->T RPI, size, format ,94,Assem3, $ T->O RPI, size, format ,, $ proxy config size, format ,, $ target config size, format "EO Digital I/O, IO-Link 8 byte with Status", $ Connection Name "Exclusive Owner Connection of Digital I/O, IO-Link 8 byte with Status", $ help string "20 04 24 01 2C 85 2C 6F"!$ Path Connection4 = 0x04010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = application type: listen-only $ 25 = application type: input-only $ 26 = application type: exclusive-owner $ 27 = application type: redundant-owner $ 28-30 = reserved $ 31 = Direction: Client = 0 / Server = 1 0x44640405, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved ,258,Assem6, $ O->T RPI, size, format ,286,Assem5, $ T->O RPI, size, format ,, $ proxy config size, format ,, $ target config size, format "EO Digital I/O, IO-Link 32 byte with Status", $ Connection Name "Exclusive Owner Connection of IO-Link Digital I/O, IO-Link 32 byte with Status", $ help string "20 04 24 01 2C 86 2C 70"!$ Path Connection5 = 0x02010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = application type: listen-only $ 25 = application type: input-only $ 26 = application type: exclusive-owner $ 27 = application type: redundant-owner $ 28-30 = reserved $ 31 = Direction: Client = 0 / Server = 1 0x44640305, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved ,0,, $ O->T RPI, size, format ,30,Assem7, $ T->O RPI, size, format ,, $ proxy config size, format ,, $ target config size, format "IO Digital In with Status", $ Connection Name "Input Only Connection of Digital In with Status", $ help string "20 04 24 01 2C C5 2C 7E"!$ Path Connection6 = 0x02010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = application type: listen-only $ 25 = application type: input-only $ 26 = application type: exclusive-owner $ 27 = application type: redundant-owner $ 28-30 = reserved $ 31 = Direction: Client = 0 / Server = 1 0x44640305, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved ,0,, $ O->T RPI, size, format ,46,Assem1, $ T->O RPI, size, format ,, $ proxy config size, format ,, $ target config size, format "IO Digital In, IO-Link In 2 byte with Status", $ Connection Name "Input Only Connection of Digital In, IO-Link In 2 byte with Status", $ help string "20 04 24 01 2C C5 2C 6E"!$ Path Connection7 = 0x02010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = application type: listen-only $ 25 = application type: input-only $ 26 = application type: exclusive-owner $ 27 = application type: redundant-owner $ 28-30 = reserved $ 31 = Direction: Client = 0 / Server = 1 0x44640305, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved ,0,, $ O->T RPI, size, format ,94,Assem3, $ T->O RPI, size, format ,, $ proxy config size, format ,, $ target config size, format "IO Digital In, IO-Link In 8 byte with Status", $ Connection Name "Input Only Connection of Digital In, IO-Link In 8 byte with Status", $ help string "20 04 24 01 2C C5 2C 6F"!$ Path Connection8 = 0x02010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = application type: listen-only $ 25 = application type: input-only $ 26 = application type: exclusive-owner $ 27 = application type: redundant-owner $ 28-30 = reserved $ 31 = Direction: Client = 0 / Server = 1 0x44640305, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved ,0,, $ O->T RPI, size, format ,286,Assem5, $ T->O RPI, size, format ,, $ proxy config size, format ,, $ target config size, format "IO Digital In, IO-Link In 32 byte with Status", $ Connection Name "Input Only Connection of Digital In, IO-Link In 32 byte with Status", $ help string "20 04 24 01 2C C5 2C 70"!$ Path $ Connection9 = $ 0x04010002, $ 0-15 = supported transport classes $ $ 16 = trigger: cyclic $ $ 17 = trigger: change of state $ $ 18 = trigger: application $ $ 19-23 = trigger: reserved $ $ 24 = application type: listen-only $ $ 25 = application type: input-only $ $ 26 = application type: exclusive-owner $ $ 27 = application type: redundant-owner $ $ 28-30 = reserved $ $ 31 = Direction: Client = 0 / Server = 1 $ 0x44640405, $ 0 = O->T fixed size supported $ $ 1 = O->T variable size supported $ $ 2 = T->O fixed size supported $ $ 3 = T->O variable size supported $ $ 4-5 = O->T number of bytes per slot (obsolete) $ $ 6-7 = T->O number of bytes per slot (obsolete) $ $ 8-10 = O->T Real time transfer format $ $ 11 = reserved $ $ 12-14 = T->O Real time transfer format $ $ 15 = reserved $ $ 16 = O->T connection type: NULL $ $ 17 = O->T connection type: MULTICAST $ $ 18 = O->T connection type: POINT2POINT $ $ 19 = O->T connection type: reserved $ $ 20 = T->O connection type: NULL $ $ 21 = T->O connection type: MULTICAST $ $ 22 = T->O connection type: POINT2POINT $ $ 23 = T->O connection type: reserved $ $ 24 = O->T priority: LOW $ $ 25 = O->T priority: HIGH $ $ 26 = O->T priority: SCHEDULED $ $ 27 = O->T priority: reserved $ $ 28 = T->O priority: LOW $ $ 29 = T->O priority: HIGH $ $ 30 = T->O priority: SCHEDULED $ $ 31 = T->O priority: reserved $ ,0,, $ O->T RPI, size, format $ ,,Assem7, $ T->O RPI, size, format $ ,, $ proxy config size, format $ ,, $ target config size, format $ "EO Digital In with Status", $ Connection Name $ "Exclusive Owner Connection of Digital In with Status", $ help string $ "20 04 24 01 2C C4 2C 7E"!$ Path $ Connection10 = $ 0x04010002, $ 0-15 = supported transport classes $ $ 16 = trigger: cyclic $ $ 17 = trigger: change of state $ $ 18 = trigger: application $ $ 19-23 = trigger: reserved $ $ 24 = application type: listen-only $ $ 25 = application type: input-only $ $ 26 = application type: exclusive-owner $ $ 27 = application type: redundant-owner $ $ 28-30 = reserved $ $ 31 = Direction: Client = 0 / Server = 1 $ 0x44640405, $ 0 = O->T fixed size supported $ $ 1 = O->T variable size supported $ $ 2 = T->O fixed size supported $ $ 3 = T->O variable size supported $ $ 4-5 = O->T number of bytes per slot (obsolete) $ $ 6-7 = T->O number of bytes per slot (obsolete) $ $ 8-10 = O->T Real time transfer format $ $ 11 = reserved $ $ 12-14 = T->O Real time transfer format $ $ 15 = reserved $ $ 16 = O->T connection type: NULL $ $ 17 = O->T connection type: MULTICAST $ $ 18 = O->T connection type: POINT2POINT $ $ 19 = O->T connection type: reserved $ $ 20 = T->O connection type: NULL $ $ 21 = T->O connection type: MULTICAST $ $ 22 = T->O connection type: POINT2POINT $ $ 23 = T->O connection type: reserved $ $ 24 = O->T priority: LOW $ $ 25 = O->T priority: HIGH $ $ 26 = O->T priority: SCHEDULED $ $ 27 = O->T priority: reserved $ $ 28 = T->O priority: LOW $ $ 29 = T->O priority: HIGH $ $ 30 = T->O priority: SCHEDULED $ $ 31 = T->O priority: reserved $ ,0,, $ O->T RPI, size, format $ ,,Assem1, $ T->O RPI, size, format $ ,, $ proxy config size, format $ ,, $ target config size, format $ "EO Digital In, IO-Link In 2 byte with Status", $ Connection Name $ "Exclusive Owner Connection of Digital In, IO-Link In 2 byte with Status", $ help string $ "20 04 24 01 2C C4 2C 6E"!$ Path $ Connection11 = $ 0x04010002, $ 0-15 = supported transport classes $ $ 16 = trigger: cyclic $ $ 17 = trigger: change of state $ $ 18 = trigger: application $ $ 19-23 = trigger: reserved $ $ 24 = application type: listen-only $ $ 25 = application type: input-only $ $ 26 = application type: exclusive-owner $ $ 27 = application type: redundant-owner $ $ 28-30 = reserved $ $ 31 = Direction: Client = 0 / Server = 1 $ 0x44640405, $ 0 = O->T fixed size supported $ $ 1 = O->T variable size supported $ $ 2 = T->O fixed size supported $ $ 3 = T->O variable size supported $ $ 4-5 = O->T number of bytes per slot (obsolete) $ $ 6-7 = T->O number of bytes per slot (obsolete) $ $ 8-10 = O->T Real time transfer format $ $ 11 = reserved $ $ 12-14 = T->O Real time transfer format $ $ 15 = reserved $ $ 16 = O->T connection type: NULL $ $ 17 = O->T connection type: MULTICAST $ $ 18 = O->T connection type: POINT2POINT $ $ 19 = O->T connection type: reserved $ $ 20 = T->O connection type: NULL $ $ 21 = T->O connection type: MULTICAST $ $ 22 = T->O connection type: POINT2POINT $ $ 23 = T->O connection type: reserved $ $ 24 = O->T priority: LOW $ $ 25 = O->T priority: HIGH $ $ 26 = O->T priority: SCHEDULED $ $ 27 = O->T priority: reserved $ $ 28 = T->O priority: LOW $ $ 29 = T->O priority: HIGH $ $ 30 = T->O priority: SCHEDULED $ $ 31 = T->O priority: reserved $ ,0,, $ O->T RPI, size, format $ ,,Assem3, $ T->O RPI, size, format $ ,, $ proxy config size, format $ ,, $ target config size, format $ "EO Digital In, IO-Link In 8 byte with Status", $ Connection Name $ "Exclusive Owner Connection of Digital In, IO-Link In 8 byte with Status", $ help string $ "20 04 24 01 2C C4 2C 6F"!$ Path $ Connection12 = $ 0x04010002, $ 0-15 = supported transport classes $ $ 16 = trigger: cyclic $ $ 17 = trigger: change of state $ $ 18 = trigger: application $ $ 19-23 = trigger: reserved $ $ 24 = application type: listen-only $ $ 25 = application type: input-only $ $ 26 = application type: exclusive-owner $ $ 27 = application type: redundant-owner $ $ 28-30 = reserved $ $ 31 = Direction: Client = 0 / Server = 1 $ 0x44640405, $ 0 = O->T fixed size supported $ $ 1 = O->T variable size supported $ $ 2 = T->O fixed size supported $ $ 3 = T->O variable size supported $ $ 4-5 = O->T number of bytes per slot (obsolete) $ $ 6-7 = T->O number of bytes per slot (obsolete) $ $ 8-10 = O->T Real time transfer format $ $ 11 = reserved $ $ 12-14 = T->O Real time transfer format $ $ 15 = reserved $ $ 16 = O->T connection type: NULL $ $ 17 = O->T connection type: MULTICAST $ $ 18 = O->T connection type: POINT2POINT $ $ 19 = O->T connection type: reserved $ $ 20 = T->O connection type: NULL $ $ 21 = T->O connection type: MULTICAST $ $ 22 = T->O connection type: POINT2POINT $ $ 23 = T->O connection type: reserved $ $ 24 = O->T priority: LOW $ $ 25 = O->T priority: HIGH $ $ 26 = O->T priority: SCHEDULED $ $ 27 = O->T priority: reserved $ $ 28 = T->O priority: LOW $ $ 29 = T->O priority: HIGH $ $ 30 = T->O priority: SCHEDULED $ $ 31 = T->O priority: reserved $ ,0,, $ O->T RPI, size, format $ ,,Assem5, $ T->O RPI, size, format $ ,, $ proxy config size, format $ ,, $ target config size, format $ "EO Digital In, IO-Link In 32 byte with Status", $ Connection Name $ "Exclusive Owner Connection of Digital In, IO-Link In 32 byte with Status", $ help string $ "20 04 24 01 2C C4 2C 70"!$ Path $ Connection13 = $ 0x01010002, $ 0-15 = supported transport classes $ $ 16 = trigger: cyclic $ $ 17 = trigger: change of state $ $ 18 = trigger: application $ $ 19-23 = trigger: reserved $ $ 24 = application type: listen-only $ $ 25 = application type: input-only $ $ 26 = application type: exclusive-owner $ $ 27 = application type: redundant-owner $ $ 28-30 = reserved $ $ 31 = Direction: Client = 0 / Server = 1 $ 0x44240305, $ 0 = O->T fixed size supported $ $ 1 = O->T variable size supported $ $ 2 = T->O fixed size supported $ $ 3 = T->O variable size supported $ $ 4-5 = O->T number of bytes per slot (obsolete) $ $ 6-7 = T->O number of bytes per slot (obsolete) $ $ 8-10 = O->T Real time transfer format $ $ 11 = reserved $ $ 12-14 = T->O Real time transfer format $ $ 15 = reserved $ $ 16 = O->T connection type: NULL $ $ 17 = O->T connection type: MULTICAST $ $ 18 = O->T connection type: POINT2POINT $ $ 19 = O->T connection type: reserved $ $ 20 = T->O connection type: NULL $ $ 21 = T->O connection type: MULTICAST $ $ 22 = T->O connection type: POINT2POINT $ $ 23 = T->O connection type: reserved $ $ 24 = O->T priority: LOW $ $ 25 = O->T priority: HIGH $ $ 26 = O->T priority: SCHEDULED $ $ 27 = O->T priority: reserved $ $ 28 = T->O priority: LOW $ $ 29 = T->O priority: HIGH $ $ 30 = T->O priority: SCHEDULED $ $ 31 = T->O priority: reserved $ ,0,, $ O->T RPI, size, format $ ,,Assem7, $ T->O RPI, size, format $ ,, $ proxy config size, format $ ,, $ target config size, format $ "LO Digital In with status", $ Connection Name $ "Listen Only connection with digital input", $ help string $ "20 04 24 01 2C C6 2C 7E"!$ Path $ $ Connection14 = $ 0x01010002, $ 0-15 = supported transport classes $ $ 16 = trigger: cyclic $ $ 17 = trigger: change of state $ $ 18 = trigger: application $ $ 19-23 = trigger: reserved $ $ 24 = application type: listen-only $ $ 25 = application type: input-only $ $ 26 = application type: exclusive-owner $ $ 27 = application type: redundant-owner $ $ 28-30 = reserved $ $ 31 = Direction: Client = 0 / Server = 1 $ 0x44240305, $ 0 = O->T fixed size supported $ $ 1 = O->T variable size supported $ $ 2 = T->O fixed size supported $ $ 3 = T->O variable size supported $ $ 4-5 = O->T number of bytes per slot (obsolete) $ $ 6-7 = T->O number of bytes per slot (obsolete) $ $ 8-10 = O->T Real time transfer format $ $ 11 = reserved $ $ 12-14 = T->O Real time transfer format $ $ 15 = reserved $ $ 16 = O->T connection type: NULL $ $ 17 = O->T connection type: MULTICAST $ $ 18 = O->T connection type: POINT2POINT $ $ 19 = O->T connection type: reserved $ $ 20 = T->O connection type: NULL $ $ 21 = T->O connection type: MULTICAST $ $ 22 = T->O connection type: POINT2POINT $ $ 23 = T->O connection type: reserved $ $ 24 = O->T priority: LOW $ $ 25 = O->T priority: HIGH $ $ 26 = O->T priority: SCHEDULED $ $ 27 = O->T priority: reserved $ $ 28 = T->O priority: LOW $ $ 29 = T->O priority: HIGH $ $ 30 = T->O priority: SCHEDULED $ $ 31 = T->O priority: reserved $ ,0,, $ O->T RPI, size, format $ ,,Assem1, $ T->O RPI, size, format $ ,, $ proxy config size, format $ ,, $ target config size, format $ "LO Digital In, IO-Link In 2 byte with status", $ Connection Name $ "Listen Only connection with IO-Link 2 bytes", $ help string $ "20 04 24 01 2C C6 2C 6E"!$ Path $ Connection15 = $ 0x01010002, $ 0-15 = supported transport classes $ $ 16 = trigger: cyclic $ $ 17 = trigger: change of state $ $ 18 = trigger: application $ $ 19-23 = trigger: reserved $ $ 24 = application type: listen-only $ $ 25 = application type: input-only $ $ 26 = application type: exclusive-owner $ $ 27 = application type: redundant-owner $ $ 28-30 = reserved $ $ 31 = Direction: Client = 0 / Server = 1 $ 0x44240305, $ 0 = O->T fixed size supported $ $ 1 = O->T variable size supported $ $ 2 = T->O fixed size supported $ $ 3 = T->O variable size supported $ $ 4-5 = O->T number of bytes per slot (obsolete) $ $ 6-7 = T->O number of bytes per slot (obsolete) $ $ 8-10 = O->T Real time transfer format $ $ 11 = reserved $ $ 12-14 = T->O Real time transfer format $ $ 15 = reserved $ $ 16 = O->T connection type: NULL $ $ 17 = O->T connection type: MULTICAST $ $ 18 = O->T connection type: POINT2POINT $ $ 19 = O->T connection type: reserved $ $ 20 = T->O connection type: NULL $ $ 21 = T->O connection type: MULTICAST $ $ 22 = T->O connection type: POINT2POINT $ $ 23 = T->O connection type: reserved $ $ 24 = O->T priority: LOW $ $ 25 = O->T priority: HIGH $ $ 26 = O->T priority: SCHEDULED $ $ 27 = O->T priority: reserved $ $ 28 = T->O priority: LOW $ $ 29 = T->O priority: HIGH $ $ 30 = T->O priority: SCHEDULED $ $ 31 = T->O priority: reserved $ ,0,, $ O->T RPI, size, format $ ,,Assem3, $ T->O RPI, size, format $ ,, $ proxy config size, format $ ,, $ target config size, format $ "LO Digital In, IO-Link In 8 byte with status", $ Connection Name $ "Listen Only connection with IO-Link 8 bytes", $ help string $ "20 04 24 01 2C C6 2C 6F"!$ Path $ Connection16 = $ 0x01010002, $ 0-15 = supported transport classes $ $ 16 = trigger: cyclic $ $ 17 = trigger: change of state $ $ 18 = trigger: application $ $ 19-23 = trigger: reserved $ $ 24 = application type: listen-only $ $ 25 = application type: input-only $ $ 26 = application type: exclusive-owner $ $ 27 = application type: redundant-owner $ $ 28-30 = reserved $ $ 31 = Direction: Client = 0 / Server = 1 $ 0x44240305, $ 0 = O->T fixed size supported $ $ 1 = O->T variable size supported $ $ 2 = T->O fixed size supported $ $ 3 = T->O variable size supported $ $ 4-5 = O->T number of bytes per slot (obsolete) $ $ 6-7 = T->O number of bytes per slot (obsolete) $ $ 8-10 = O->T Real time transfer format $ $ 11 = reserved $ $ 12-14 = T->O Real time transfer format $ $ 15 = reserved $ $ 16 = O->T connection type: NULL $ $ 17 = O->T connection type: MULTICAST $ $ 18 = O->T connection type: POINT2POINT $ $ 19 = O->T connection type: reserved $ $ 20 = T->O connection type: NULL $ $ 21 = T->O connection type: MULTICAST $ $ 22 = T->O connection type: POINT2POINT $ $ 23 = T->O connection type: reserved $ $ 24 = O->T priority: LOW $ $ 25 = O->T priority: HIGH $ $ 26 = O->T priority: SCHEDULED $ $ 27 = O->T priority: reserved $ $ 28 = T->O priority: LOW $ $ 29 = T->O priority: HIGH $ $ 30 = T->O priority: SCHEDULED $ $ 31 = T->O priority: reserved $ ,0,, $ O->T RPI, size, format $ ,,Assem5, $ T->O RPI, size, format $ ,, $ proxy config size, format $ ,, $ target config size, format $ "LO Digital In, IO-Link In 32 byte with status", $ Connection Name $ "Listen Only connection with IO-Link 32 bytes", $ help string $ "20 04 24 01 2C C6 2C 70"!路径[能力]最大IOSCunctions=5maxMsgConnections=5Tspec1=TxRx2 400Tspec2=TxRx2924000修订版=3Object_Name=Devie级环对象Object_Class_Code=0x47MaxInst=1数表Satistic#Instances=1最大数_Of_Dynic_Instances=0Ring_Supervisorapi类分配数=1实例_属性=1、2、10、12services=0x0E实例服务=0x010E$临时值ENetQCT1[TCP/IP界面类]修订版=4Object_Name=TCP/IP接口对象Object_Class_Code=0xF5MaxInst=1数表Satistic#Instances=1最大数_Of_Dynic_Instances=0ENetQCT1=65010校正=4Object_Name=Ethernet链接对象Object_Class_Code=0xF6MaxInst=2数表静态=2最大数_Of_Dynic_Instances=0界面Label1=Ethernet端口1界面Label2=Ethernet端口2界面类型1=2二元双对界面二二分二分二分二分一分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二分二2元双对调Object_Name=qos对象Object_Class_Code=0x48MaxInst=1数表Satistic#Instances=1最大数_Of_Dynic_Instances=0类分配数=1实例目录45678services=0x0E实例_services=0x0E0x10[47_Groups] Group1 = "Port1 Device info", 6, 1013, 1014, 1015, 1017, 1018, 1021!Group2 = "Port2 Device info", 6, 1041, 1042, 1043, 1045, 1046, 1049!Group3 = "Port3 Device info", 6, 1069, 1070, 1071, 1073, 1074, 1077!Group4 = "Port4 Device info", 6, 1097, 1098, 1099, 1111, 1112, 1115!Group5 = "Port5 Device info", 6, 1135, 1136, 1137, 1139, 1140, 1143!Group6 = "Port6 Device info", 6, 1163, 1164, 1165, 1167, 1168, 1171!Group7 = "Port7 Device info", 6, 1191, 1192, 1193, 1195, 1196, 1199!Group8 = "Port8 Device info", 6, 1219, 1220, 1221, 1223, 1224, 1227;