EZ-EDS版本3.29.1.20210209生成电子数据表CreateDate=07-28-2020创建时间= 5:08:33ModDate=11-18-2021ModTime=10:04:00修订版=1.0HomeurLssVendCode=68VendName=Eaton公司ProdType=23ProdTypeStrssProdCode=33549MajRev=1MinRev=1ProdName=AmpgardRVSSEtherNet卡C445XC-E图标=C445_EDC.co第1类EtherNetIP$ **************************************************************************************** $ * $ * Generated EDS Data: $ * $ **************************************************************************************** [Params] Param1 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0004, $ Descriptor 0xC8, $ Data Type 4, $ Data Size in Bytes "RPI Range", $ Data Name "", $ Units "This parameter limits the range of the RPI (Requested Packet Interval) value", $ Help String 5000,5000000,20000, $ min, max, default data values 1,1000,1,0, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links 1!$ Decimal Places Param2 = 0, $ reserved, shall equal 0 6,"20 2C 24 01 30 6A", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC6, $ Data Type 1, $ Data Size in bytes "Motor Overload Alarm Level", $ name "%", $ units "Motor Overload Alarm Level", $ help string 60,100,80, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param3 = 0, $ reserved, shall equal 0 6,"20 2D 24 02 30 03", $ Link Path Size, Link Path 0x0030, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "Motor Control Status Bit6 (At Reference) Profile2", $ name "", $ units "Motor Control Status Bit6 (At Reference) Profile1", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param12 = $ C: 0x04, I: 0x03, A: 0x03 - CIP o/p assembly3 Basic Motor Starter 0, $ First field shall equal 0 ,, $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xD1, $ Data Type 1, $ Data Size in Bytes "Basic Motor Starter o/p assembly", $ Data Name "", $ Units "Basic Motor Starter o/p assembly", $ Help String 0,0xFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param13 = $ C: 0x04, I: 0x3C, A: 0x03 - Input Status Word - Basic 0, $ First field shall equal 0 ,, $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xD1, $ Data Type 1, $ Data Size in Bytes "Basic Motor Starter I/p status word assembly", $ Data Name "", $ Units "Basic Motor Starter I/p status word assembly", $ Help String 0,0xFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param14 = $ C: 0x04, I: 0x3D, A: 0x03 - Input Status Word - Extended 0, $ First field shall equal 0 ,, $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xD1, $ Data Type 1, $ Data Size in Bytes "Basic Motor Starter I/p status word assembly_1", $ Data Name "", $ Units "Basic Motor Starter I/p status word assembly", $ Help String 0,0xFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param15 = $ C: 0x04, I: 0x64, A: 0x03 - CIP ASM Head C445-100 Status, Current Monitoring 0, $ First field shall equal 0 ,, $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC9, $ Data Type 8, $ Data Size in Bytes "Status and Current", $ Data Name "", $ Units "Status and Current", $ Help String 0,0xFFFFFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param16 = $ C: 0x04, I: 0x64, A: 0x03 - C441 Packed Device Status Bit Array 0, $ First field shall equal 0 ,, $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xD2, $ Data Type 2, $ Data Size in Bytes "Device Status", $ Data Name "", $ Units "Device Status", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param17 = $ C: 0x04, I: 0x64, A: 0x03 - Motor Current Phase A - Scaled 0, $ First field shall equal 0 6,"20 2C 24 01 30 08", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "IA (L1)", $ Data Name "A", $ Units "IA (L1)", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param18 = $ C: 0x04, I: 0x64, A: 0x03 - Motor Current Phase B - Scaled 0, $ First field shall equal 0 6,"20 2C 24 01 30 09", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "IB (L2)", $ Data Name "A", $ Units "IB (L2)", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param19 = $ C: 0x04, I: 0x64, A: 0x03 - Motor Current Phase C - Scaled 0, $ First field shall equal 0 6,"20 2C 24 01 30 0A", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "IC (L3)", $ Data Name "A", $ Units "IC (L3)", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param25 = $ C: 0x04, I: 0x65, A: 0x03 - Motor Current Average - Scaled 0, $ First field shall equal 0 6,"20 2C 24 01 30 05", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "I Average", $ Data Name "A", $ Units "I Average", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param26 = $ C: 0x04, I: 0x65, A: 0x03 - Line Voltage LL Phases AB 0, $ First field shall equal 0 6,"20 93 24 01 30 01", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Voltage AB (L1-L2)", $ Data Name "V", $ Units "Voltage AB (L1-L2)", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param27 = $ C: 0x04, I: 0x65, A: 0x03 - Line Voltage LL Phases BC 0, $ First field shall equal 0 6,"20 93 24 01 30 02", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Voltage BC (L2-L3)", $ Data Name "V", $ Units "Voltage BC (L2-L3)", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param28 = $ C: 0x04, I: 0x65, A: 0x03 - Line Voltage LL Phases CA 0, $ First field shall equal 0 6,"20 93 24 01 30 03", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Voltage CA (L3-L1)", $ Data Name "V", $ Units "Voltage CA (L3-L1)", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param29 = $ C: 0x04, I: 0x65, A: 0x03 - Line Voltage LL Average 0, $ First field shall equal 0 6,"20 93 24 01 30 04", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Average Line-to-Line Voltage", $ Data Name "V", $ Units "Average Line-to-Line Voltage", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param30 = $ C: 0x04, I: 0x65, A: 0x03 - Total Watts for all three phases 0, $ First field shall equal 0 6,"20 A1 24 01 30 17", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Total Watts", $ Data Name "KW", $ Units "Total Watts", $ Help String 0x0000,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param31 = $ C: 0x04, I: 0x65, A: 0x03 - Line V Unbalance Percent 0, $ First field shall equal 0 ,, $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Voltage Unbalance", $ Data Name "%", $ Units "Voltage Unbalance", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param32 = $ C: 0x04, I: 0x65, A: 0x03 - Motor I Unbalance Percent 0, $ First field shall equal 0 ,, $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Current Unbalance", $ Data Name "%FLA", $ Units "Current Unbalance", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param33 = $ C: 0x04, I: 0x65, A: 0x03 - Power Apparent Power Factor 0, $ First field shall equal 0 6,"20 A1 24 01 30 11", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC3, $ Data Type 2, $ Data Size in Bytes "Power Factor x 100", $ Data Name "%", $ Units "Power Factor Scaled", $ Help String 0x8000,0x7FFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param34 = $ C: 0x04, I: 0x65, A: 0x03 - Line Frequency - Scaled 0, $ First field shall equal 0 6,"20 93 24 01 30 08", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Line Frequency x100", $ Data Name "Hz", $ Units "Line Frequency x100", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param35 = $ C: 0x04, I: 0x65, A: 0x03 - Tripped Status Bits 0, $ First field shall equal 0 6,"20 29 24 01 30 67", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xD3, $ Data Type 4, $ Data Size in Bytes "Tripped Status Bits", $ Data Name "", $ Units "Tripped Status Bits", $ Help String 0,0xFFFFFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param36 = $ C: 0x04, I: 0x65, A: 0x03 - Warning Status Bits 0, $ First field shall equal 0 6,"20 29 24 01 30 68", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xD3, $ Data Type 4, $ Data Size in Bytes "Warning Status Bits", $ Data Name "", $ Units "Warning Status Bits", $ Help String 0,0xFFFFFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param37 = $ C: 0x04, I: 0x65, A: 0x03 - Thermal memory Percent 0, $ First field shall equal 0 6,"20 2C 24 64 30 07", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Thermal Memory Percent", $ Data Name "%", $ Units "Thermal Memory Percent", $ Help String 0,0xFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param38 = $ C: 0x04, I: 0x66, A: 0x03 - CIP ASM Head C445-102 0, $ First field shall equal 0 ,, $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Status and Current and Remote Inputs_1", $ Data Name "", $ Units "Status and Current and Remote Inputs", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param43 = $ C: 0x29, I: 0x01, A: 0x03 - Fieldbus Motor Control 0, $ First field shall equal 0 6,"20 29 24 01 30 03", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC1, $ Data Type 1, $ Data Size in Bytes "Fieldbus Motor Control Run Command", $ Data Name "", $ Units "Fieldbus Motor Control", $ Help String 0,1,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param44 = $ C: 0x29, I: 0x01, A: 0x07 - Motor Control Status (Running1, Running2, Remote, Tripped, Warned) 0, $ First field shall equal 0 6,"20 29 24 01 30 07", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC1, $ Data Type 1, $ Data Size in Bytes "Motor Control Status Bit0 (Run Status)", $ Data Name "", $ Units "Motor Control Status", $ Help String 0,1,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param45 = $ C: 0x29, I: 0x01, A: 0x09 - Motor Control Status (Running1, Running2, Remote, Tripped, Warned) 0, $ First field shall equal 0 6,"20 29 24 01 30 09", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC1, $ Data Type 1, $ Data Size in Bytes "Motor Control Status BIT5 (Ready Status)", $ Data Name "", $ Units "Motor Control Status", $ Help String 0,1,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param46 = $ C: 0x29, I: 0x01, A: 0x0A - Motor Control Status (Running1, Running2, Remote, Tripped, Warned) 0, $ First field shall equal 0 6,"20 29 24 01 30 0A", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC1, $ Data Type 1, $ Data Size in Bytes "Motor Control Status BIT2 (Fault Status)", $ Data Name "", $ Units "Motor Control Status", $ Help String 0,1,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param47 = $ C: 0x29, I: 0x01, A: 0x0B - Motor Control Status (Running1, Running2, Remote, Tripped, Warned) 0, $ First field shall equal 0 6,"20 29 24 01 30 0B", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC1, $ Data Type 1, $ Data Size in Bytes "Motor Control Status BIT3 (Warning Status)", $ Data Name "", $ Units "Motor Control Status", $ Help String 0,1,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param48 = $ C: 0x29, I: 0x01, A: 0x0C - Fieldbus Motor Control 0, $ First field shall equal 0 6,"20 29 24 01 30 0C", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC1, $ Data Type 1, $ Data Size in Bytes "Fieldbus Motor Control Reset Command", $ Data Name "", $ Units "Fieldbus Motor Control", $ Help String 0,1,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param49 = $ C: 0x29, I: 0x01, A: 0x0F - Motor Control Status (Running1, Running2, Remote, Tripped, Warned) 0, $ First field shall equal 0 6,"20 29 24 01 30 0F", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC1, $ Data Type 1, $ Data Size in Bytes "Motor Control Status Bit1 (Remote Enabled)", $ Data Name "", $ Units "Motor Control Status", $ Help String 0,1,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param50 = $ C: 0x29, I: 0x01, A: 0x65 - Fieldbus Motor Control 0, $ First field shall equal 0 6,"20 29 24 01 30 65", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xD1, $ Data Type 1, $ Data Size in Bytes "Fieldbus Motor Control Command Word", $ Data Name "", $ Units "Fieldbus Motor Control", $ Help String 0,0xFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param51 = $ C: 0x29, I: 0x01, A: 0x66 - Motor Control Status (Running1, Running2, Remote, Tripped, Warned) 0, $ First field shall equal 0 6,"20 29 24 01 30 66", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xD1, $ Data Type 1, $ Data Size in Bytes "Motor Control Status Word", $ Data Name "", $ Units "Motor Control Status", $ Help String 0,0xFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param52 = 0, $ reserved, shall equal 0 6,"20 29 24 01 30 70", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "Motor Control Status Bit4 (Inhibited)", $ name "", $ units "Motor Control Status", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param53 = 0, $ reserved, shall equal 0 6,"20 29 24 01 30 07", $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "Motor Control Status Bit7 (Manual Bypass Status)", $ name "", $ units "Motor Control Status", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links !$ decimal places Param54 = $ C: 0x29, I: 0x01, A: 0x69 - Active Fault 0, $ First field shall equal 0 6,"20 29 24 01 30 69", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Active Fault", $ Data Name "", $ Units "Active Fault", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param55 = $ C: 0x29, I: 0x01, A: 0x6A - Active Warning 0, $ First field shall equal 0 6,"20 29 24 01 30 6A", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Active Warning", $ Data Name "", $ Units "Active Warning", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param56 = $ C: 0x29, I: 0x01, A: 0x6B - Motor Controller Status 0, $ First field shall equal 0 6,"20 29 24 01 30 6B", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xD3, $ Data Type 4, $ Data Size in Bytes "Motor Controller Status", $ Data Name "", $ Units "Motor Controller Status", $ Help String 0,0xFFFFFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param57 = $ C: 0x29, I: 0x01, A: 0x6C - Pre-start sub-fault code 0, $ First field shall equal 0 6,"20 29 24 01 30 6C", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Pre-start sub-fault code ", $ Data Name "", $ Units "Pre-start sub-fault code ", $ Help String 0,0xFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param65 = $ C: 0x2C, I: 0x01, A: 0x65 - Thermal Bucket Ultimate Trip Level 0, $ First field shall equal 0 6,"20 2C 24 01 30 65", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Thermal Bucket Ultimate Trip Level", $ Data Name "%", $ Units "Thermal Bucket Ultimate Trip Level", $ Help String 75,120,100, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param66 = $ C: 0x2C, I: 0x01, A: 0x66 - Motor Current Scale Factor 0, $ First field shall equal 0 6,"20 2C 24 01 30 66", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "I Scale Factor", $ Data Name "", $ Units "I Scale Factor", $ Help String 0,0xFFFF,1, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param67 = $ C: 0x2C, I: 0x01, A: 0x67 - Motor Current Average Percent FLA 0, $ First field shall equal 0 6,"20 2C 24 01 30 67", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "I Average % of FLA (Nominal Current)", $ Data Name "", $ Units "I Average % of FLA (Nominal Current)", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param68 = $ C: 0x2C, I: 0x01, A: 0x68 - Thermal capacity level remaining 0, $ First field shall equal 0 6,"20 2C 24 01 30 68", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Remaining Thermal Capacity", $ Data Name "", $ Units "Remaining Thermal Capacity", $ Help String 0,0xFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param69 = $ C: 0x2C, I: 0x01, A: 0x69 - Time to Trip (overload) 0, $ First field shall equal 0 6,"20 2C 24 01 30 69", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Time to Trip Overload",$ Data Name "seconds", $ Units "Time to Trip Overload",$ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param70 = $ C: 0x2C, I: 0x01, A: 0x6A - Locked Rotor Time 0, $ First field shall equal 0 6,"20 2C 24 01 30 6D", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Locked Rotor Time", $ Data Name "seconds", $ Units "Locked Rotor Time", $ Help String 1,120,18, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param71 = $ C: 0x2C, I: 0x01, A: 0x6B - CT Ratio - Primary 0, $ First field shall equal 0 6,"20 2C 24 01 30 6B", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "CT Ratio - Primary", $ Data Name "", $ Units "CT Ratio - Primary", $ Help String 25,1000,1000, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param72 = $ C: 0x2C, I: 0x01, A: 0x6C - Time to Trip (overload) 0, $ First field shall equal 0 6,"20 2C 24 01 30 6C", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Time to Trip Overload_minutes", $ Data Name "minutes", $ Units "Time to Trip Overload",$ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param74 = $ C: 0x2C, I: 0x01, A: 0x6E - Locked Rotor Current 0, $ First field shall equal 0 6,"20 2C 24 01 30 6E", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Locked Rotor Current", $ Data Name "%FLA", $ Units "Locked Rotor Current", $ Help String 300,1000,600, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param75 = $ C: 0x2C, I: 0x01, A: 0x6F - Temperature of pole 1 0, $ First field shall equal 0 6,"20 2C 24 01 30 6F", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Temperature of pole 1",$ Data Name "�C", $ Units "Temperature of pole 1",$ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param76 = $ C: 0x2C, I: 0x01, A: 0x70 - Temperature of pole 2 0, $ First field shall equal 0 6,"20 2C 24 01 30 70", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Temperature of pole 2",$ Data Name "�C", $ Units "Temperature of pole 2",$ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param77 = $ C: 0x2C, I: 0x01, A: 0x71 - Temperature of pole 3 0, $ First field shall equal 0 6,"20 2C 24 01 30 71", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Temperature of pole 3",$ Data Name "�C", $ Units "Temperature of pole 3",$ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param78 = $ C: 0x2C, I: 0x01, A: 0x72 - Maximum Temperature 0, $ First field shall equal 0 6,"20 2C 24 01 30 72", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Maximum Temperature", $ Data Name "�C", $ Units "Maximum Temperature", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param79 = $ C: 0x2C, I: 0x01, A: 0x73 - Max Temperature of pole 1 0, $ First field shall equal 0 6,"20 2C 24 01 30 73", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Max Temperature of pole 1", $ Data Name "�C", $ Units "Max Temperature of pole 1", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param80 = $ C: 0x2C, I: 0x01, A: 0x74 - Max Temperature of pole 2 0, $ First field shall equal 0 6,"20 2C 24 01 30 74", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Max Temperature of pole 2", $ Data Name "�C", $ Units "Max Temperature of pole 2", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param81 = $ C: 0x2C, I: 0x01, A: 0x75 - Max Temperature of pole 3 0, $ First field shall equal 0 6,"20 2C 24 01 30 75", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Max Temperature of pole 3", $ Data Name "�C", $ Units "Max Temperature of pole 3", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param82 = $ C: 0x2D, I: 0x01, A: 0x03 - Motor Controller Status 0, $ First field shall equal 0 6,"20 2D 24 01 30 03", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC1, $ Data Type 1, $ Data Size in Bytes "Motor Control Status Bit6 (At Reference) Profile1", $ Data Name "", $ Units "Motor Control Status Bit6 (At Reference) Profile1", $ Help String 0,1,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param83 = $ C: 0x2D, I: 0x01, A: 0x04 - Used to select the desired control profile (soft reset required) 0, $ First field shall equal 0 6,"20 2D 24 01 30 04", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes " Active Starter Profile Profile 1", $ Data Name "", $ Units " Active Starter Profile Profile 1", $ Help String 0,15,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param85 = $ C: 0x2D, I: 0x01, A: 0x66 - Used to select the desired control profile (soft reset required) 0, $ First field shall equal 0 6,"20 2D 24 02 30 04", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes " Active Starter Profile Profile 2", $ Data Name "", $ Units " Active Starter Profile Profile 2", $ Help String 0,15,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param86 = $ C: 0x2D, I: 0x01, A: 0x67 - Used to select the desired control profile (soft reset required) 0, $ First field shall equal 0 6,"20 2D 24 01 30 05", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes " Active Stop Profile Profile 1", $ Data Name "", $ Units " Active Stop Profile Profile 1", $ Help String 0,12,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param87 = $ C: 0x2D, I: 0x01, A: 0x68 - Voltage sag limit Profile 1 0, $ First field shall equal 0 6,"20 2D 24 01 30 68", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Voltage Sag Limit Profile 1", $ Data Name "%FV", $ Units "Voltage Sag Limit Profile 1", $ Help String 0,30,10, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param88 = $ C: 0x2D, I: 0x01, A: 0x69 - Start ramp time Profile 1 0, $ First field shall equal 0 6,"20 2D 24 01 30 07", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Start Ramp Time Profile 1", $ Data Name "seconds", $ Units "Start Ramp Time Profile 1", $ Help String 1,240,15, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param89 = $ C: 0x2D, I: 0x01, A: 0x6A - Jog Voltage Profile 1 0, $ First field shall equal 0 6,"20 2D 24 01 30 6A", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Jog Voltage Profile 1",$ Data Name "%FV", $ Units "Jog Voltage Profile 1",$ Help String 0,99,30, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param90 = $ C: 0x2D, I: 0x01, A: 0x6B - Initial current Profile 1 0, $ First field shall equal 0 6,"20 2D 24 01 30 6B", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Initial Current Profile 1", $ Data Name "%FLA", $ Units "Initial Current Profile 1", $ Help String 0,1000,200, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param91 = $ C: 0x2D, I: 0x01, A: 0x6C - Initial voltage Profile 1 0, $ First field shall equal 0 6,"20 2D 24 01 30 65", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Initial Voltage Profile 1", $ Data Name "%FV", $ Units "Initial Voltage Profile 1", $ Help String 0,99,25, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param92 = $ C: 0x2D, I: 0x01, A: 0x6D - current limit Profile 1 0, $ First field shall equal 0 6,"20 2D 24 01 30 6D", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Current Limit Profile 1", $ Data Name "%", $ Units "Current Limit Profile 1", $ Help String 200,1000,400, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param93 = $ C: 0x2D, I: 0x01, A: 0x6E - max current Profile 1 0, $ First field shall equal 0 6,"20 2D 24 01 30 6E", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Max Current Profile 1",$ Data Name "%FLA", $ Units "Max Current Profile 1",$ Help String 200,1000,500, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param94 = $ C: 0x2D, I: 0x01, A: 0x6F - Stop ramp time Profile 1 0, $ First field shall equal 0 6,"20 2D 24 01 30 6F", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Stop Ramp Time Profile 1", $ Data Name "seconds", $ Units "Stop Ramp Time Profile 1", $ Help String 1,240,15, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param95 = $ C: 0x2D, I: 0x01, A: 0x70 - Deceleration initial voltage Profile 1 0, $ First field shall equal 0 6,"20 2D 24 01 30 70", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Deceleration Initial Voltage Profile 1", $ Data Name "%FV", $ Units "Deceleration Initial Voltage Profile 1", $ Help String 25,100,53, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param96 = $ C: 0x2D, I: 0x01, A: 0x71 - Deceleration final voltage Profile 1 0, $ First field shall equal 0 6,"20 2D 24 01 30 71", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Deceleration Final Voltage Profile 1", $ Data Name "%FV", $ Units "Deceleration Final Voltage Profile 1", $ Help String 5,40,20, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param97 = $ C: 0x2D, I: 0x01, A: 0x72 - Kick start enable Profile 1 0, $ First field shall equal 0 6,"20 2D 24 01 30 OC", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC1, $ Data Type 1, $ Data Size in Bytes "Kick Start Enable Profile 1", $ Data Name "", $ Units "Kick Start Enable Profile 1", $ Help String 0,1,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param98 = $ C: 0x2D, I: 0x01, A: 0x73 - Kick start voltage Profile 1 0, $ First field shall equal 0 6,"20 2D 24 01 30 0E", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Kick Start Voltage Profile 1", $ Data Name "Volts", $ Units "Kick Start Voltage Profile 1", $ Help String 10,100,50, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param99 = $ C: 0x2D, I: 0x01, A: 0x74 - Kick start time Profile 1 0, $ First field shall equal 0 6,"20 2D 24 01 30 66", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Kick Start Time Profile 1", $ Data Name "Seconds", $ Units "Kick Start Time Profile 1", $ Help String 6,120,10, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param100 = $ C: 0x2D, I: 0x01, A: 0x84 - Incomplete sequence time 0, $ First field shall equal 0 6,"20 2D 24 01 30 72", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Incomplete Sequence Time Profile 1", $ Data Name "seconds", $ Units "Incomplete Sequence Time Profile 1", $ Help String 1,250,18, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param103 = $ C: 0x2D, I: 0x02, A: 0x76 - Used to select the desired control profile (soft reset required) 0, $ First field shall equal 0 6,"20 2D 24 02 30 05", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes " Active Stop Profile Profile 2", $ Data Name "", $ Units " Active Stop Profile Profile 2", $ Help String 0,12,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param104 = $ C: 0x2D, I: 0x02, A: 0x77 - Voltage sag limit Profile 2 0, $ First field shall equal 0 6,"20 2D 24 02 30 77", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Voltage sag limit_1", $ Data Name "", $ Units "Voltage sag limit", $ Help String 5,50,20, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param105 = $ C: 0x2D, I: 0x02, A: 0x78 - Start ramp time Profile 2 0, $ First field shall equal 0 6,"20 2D 24 02 30 07", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Start ramp time Profile 2", $ Data Name "seconds", $ Units "Start ramp time Profile 2", $ Help String 1,240,15, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param106 = $ C: 0x2D, I: 0x02, A: 0x79 - RVSS Jog voltage Profile 2 0, $ First field shall equal 0 6,"20 2D 24 02 30 79", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Jog Voltage Profile 2",$ Data Name "%FV", $ Units "Jog Voltage Profile 2",$ Help String 0,99,30, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param107 = $ C: 0x2D, I: 0x02, A: 0x7A - Initial current Profile 2 0, $ First field shall equal 0 6,"20 2D 24 02 30 7A", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Initial Current Profile 2", $ Data Name "%FLA", $ Units "Initial Current Profile 1", $ Help String 0,1000,200, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param108 = $ C: 0x2D, I: 0x02, A: 0x7B - Initial voltage Profile 2 0, $ First field shall equal 0 6,"20 2D 24 02 30 65", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Initial Voltage Profile 2", $ Data Name "%FV", $ Units "Initial Voltage Profile 2", $ Help String 0,99,25, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param109 = $ C: 0x2D, I: 0x02, A: 0x7C - current limit Profile 2 0, $ First field shall equal 0 6,"20 2D 24 02 30 7C", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Current Limit Profile 2", $ Data Name "%", $ Units "Current Limit Profile 2", $ Help String 0,1000,400, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param110 = $ C: 0x2D, I: 0x02, A: 0x7D - max current Profile 2 0, $ First field shall equal 0 6,"20 2D 24 02 30 7D", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Max Current Profile 2",$ Data Name "%FLA", $ Units "Max Current Profile 2",$ Help String 200,1000,500, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param111 = $ C: 0x2D, I: 0x02, A: 0x7E - Stop ramp time Profile 2 0, $ First field shall equal 0 6,"20 2D 24 02 30 7E", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Stop Ramp Time Profile 2", $ Data Name "seconds", $ Units "Stop Ramp Time Profile 2", $ Help String 1,240,30, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param112 = $ C: 0x2D, I: 0x02, A: 0x7F - Deceleration initial voltage Profile 2 0, $ First field shall equal 0 6,"20 2D 24 02 30 7F", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Deceleration Initial Voltage Profile 2", $ Data Name "%FV", $ Units "Deceleration Initial Voltage Profile 2", $ Help String 25,100,53, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param113 = $ C: 0x2D, I: 0x02, A: 0x80 - Deceleration final voltage Profile 2 0, $ First field shall equal 0 6,"20 2D 24 02 30 80", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Deceleration Final Voltage Profile 2", $ Data Name "%FV", $ Units "Deceleration Final Voltage Profile 1", $ Help String 5,40,20, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param114 = $ C: 0x2D, I: 0x02, A: 0x81 - Kick start enable Profile 2 0, $ First field shall equal 0 6,"20 2D 24 02 30 OC", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC1, $ Data Type 1, $ Data Size in Bytes "Kick Start Enable Profile 2", $ Data Name "", $ Units "Kick Start Enable Profile 2", $ Help String 0,1,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param115 = $ C: 0x2D, I: 0x02, A: 0x82 - Kick start voltage Profile 2 0, $ First field shall equal 0 6,"20 2D 24 02 30 0E", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Kick Start Voltage Profile 2", $ Data Name "Volts", $ Units "Kick Start Voltage Profile 1", $ Help String 10,100,50, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param116 = $ C: 0x2D, I: 0x02, A: 0x83 - Kick start time Profile 2 0, $ First field shall equal 0 6,"20 2D 24 02 30 66", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Kick Start Time Profile 2", $ Data Name "seconds", $ Units "Kick Start Time Profile 2", $ Help String 6,120,10, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param117 = $ C: 0x2D, I: 0x02, A: 0x85 - Incomplete sequence time 0, $ First field shall equal 0 6,"20 2D 24 02 30 81", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Incomplete Sequence Time Profile 2", $ Data Name "seconds", $ Units "Incomplete Sequence Time Profile 2", $ Help String 1,250,18, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param118 = $ C: 0x88, I: 0x01, A: 0x01 - Base Control Module Product Hardware Revision 0, $ First field shall equal 0 6,"20 88 24 01 30 01", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Base Control Module Hardware Version", $ Data Name "", $ Units "Base Control Module Hardware Version", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param119 = $ C: 0x88, I: 0x01, A: 0x02 - Base Control Module Product Firmware Revision 0, $ First field shall equal 0 6,"20 88 24 01 30 02", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Base Control Module Firmware Version", $ Data Name "", $ Units "Base Control Module Firmware Version", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param120 = $ C: 0x88, I: 0x01, A: 0x03 - Base Control Module Device Product Serial Number 0, $ First field shall equal 0 6,"20 88 24 01 30 03", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC8, $ Data Type 4, $ Data Size in Bytes "Base Control Module Serial Number", $ Data Name "", $ Units "Base Control Module Serial Number", $ Help String 0,0xFFFFFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param121 = $ C: 0x88, I: 0x01, A: 0x04 - Base Control Module Product Code 0, $ First field shall equal 0 6,"20 88 24 01 30 04", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Base Control Module Product Code", $ Data Name "", $ Units "Base Control Module Product Code", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param122 = $ C: 0x88, I: 0x01, A: 0x05 - Base Control Module Product Sub Code 0, $ First field shall equal 0 6,"20 88 24 01 30 05", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Base Control Module Product Sub Code", $ Data Name "", $ Units "Base Control Module Product Sub Code", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param123 = $ C: 0x88, I: 0x02, A: 0x01 - Measurement Module Product Hardware Revision 0, $ First field shall equal 0 6,"20 88 24 02 30 01", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "DSP Module Hardware Version", $ Data Name "", $ Units "DSP Module Hardware Version", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param124 = $ C: 0x88, I: 0x02, A: 0x02 - Measurement Module Product Firmware Revision 0, $ First field shall equal 0 6,"20 88 24 02 30 02", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "DSP Module Firmware Version", $ Data Name "", $ Units "DSP Module Firmware Version", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param125 = $ C: 0x88, I: 0x02, A: 0x03 - Measurement Module Product Serial Number 0, $ First field shall equal 0 6,"20 88 24 02 30 03", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC8, $ Data Type 4, $ Data Size in Bytes "DSP Module Serial Number", $ Data Name "", $ Units "DSP Module Serial Number", $ Help String 0,0xFFFFFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param126 = $ C: 0x88, I: 0x02, A: 0x04 - Measurement Module Product Code 0, $ First field shall equal 0 6,"20 88 24 02 30 04", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "DSP Module Product Code", $ Data Name "", $ Units "DSP Module Product Code", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param127 = $ C: 0x88, I: 0x02, A: 0x05 - Measurement Module Product Sub Code 0, $ First field shall equal 0 6,"20 88 24 02 30 05", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "DSP Module Product Sub Code", $ Data Name "", $ Units "DSP Module Product Sub Code", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param128 = $ C: 0x88, I: 0x03, A: 0x01 - Device Hardware Revision 0, $ First field shall equal 0 6,"20 88 24 03 30 01", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Ethernet Card Hardware Rev", $ Data Name "", $ Units "Ethernet Card Hardware Rev", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param129 = $ C: 0x88, I: 0x03, A: 0x02 - Device Firmware Revision 0, $ First field shall equal 0 6,"20 88 24 03 30 02", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "EtherNet Card Product Firmware Revision", $ Data Name "", $ Units "EtherNet Card Product Firmware Revision", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param130 = $ C: 0x88, I: 0x03, A: 0x03 - Device Product Serial Number 0, $ First field shall equal 0 6,"20 88 24 03 30 03", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC8, $ Data Type 4, $ Data Size in Bytes "EtherNet Card Serial Number", $ Data Name "", $ Units "EtherNet Card Serial Number", $ Help String 0,0xFFFFFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param131 = $ C: 0x88, I: 0x03, A: 0x04 - Communication Device Product Code 0, $ First field shall equal 0 6,"20 88 24 03 30 04", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "EtherNet Card Product Code", $ Data Name "", $ Units "EtherNet Card Product Code", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param132 = $ C: 0x88, I: 0x03, A: 0x05 - Option Card Product Sub Code 0, $ First field shall equal 0 6,"20 88 24 03 30 05", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "EtherNet Card Product Sub Code", $ Data Name "", $ Units "EtherNet Card Product Sub Code", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param133 = $ C: 0x88, I: 0x04, A: 0x01 - User Interface Product Hardware Revision 0, $ First field shall equal 0 6,"20 88 24 04 30 01", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "User Interface Hardware Version", $ Data Name "", $ Units "User Interface Hardware Version", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param134 = $ C: 0x88, I: 0x04, A: 0x02 - User Interface Product Firmware Revision 0, $ First field shall equal 0 6,"20 88 24 04 30 02", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "User Interface Firmware Version", $ Data Name "", $ Units "User Interface Firmware Version", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param135 = $ C: 0x88, I: 0x04, A: 0x03 - User Interface Device Product Serial Number 0, $ First field shall equal 0 6,"20 88 24 04 30 03", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC8, $ Data Type 4, $ Data Size in Bytes "User Interface Serial Number", $ Data Name "", $ Units "User Interface Serial Number", $ Help String 0,0xFFFFFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param136 = $ C: 0x88, I: 0x04, A: 0x04 - User Interface Product Code 0, $ First field shall equal 0 6,"20 88 24 04 30 04", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "User Interface Product Code", $ Data Name "", $ Units "User Interface Product Code", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param137 = $ C: 0x88, I: 0x04, A: 0x05 - User Interface Product Sub Code 0, $ First field shall equal 0 6,"20 88 24 04 30 05", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "User Interface Product Sub Code", $ Data Name "", $ Units "User Interface Product Sub Code", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param142 = $ C: 0x93, I: 0x01, A: 0x06 - Line Voltage Phase Order 0, $ First field shall equal 0 6,"20 93 24 01 30 06", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Voltage Phase Order", $ Data Name "", $ Units "Voltage Phase Order", $ Help String 0,4,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param143 = $ C: 0x93, I: 0x01, A: 0x07 - PT Ratio (only available with external PT) - Primary 0, $ First field shall equal 0 6,"20 93 24 01 30 07", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "PT Ratio Primary", $ Data Name "", $ Units "PT Ratio Primary", $ Help String 2400,14400,4200, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param145 = $ C: 0x93, I: 0x01, A: 0x0A - Measurement Module Voltage Scale Factor 0, $ First field shall equal 0 6,"20 93 24 01 30 0A", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Voltage Scale", $ Data Name "", $ Units "Voltage Scale", $ Help String 0,0xFFFF,1, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param146 = $ C: 0x93, I: 0x01, A: 0x0B - Protection UnderVoltage Trip Level 0, $ First field shall equal 0 6,"20 93 24 01 30 0B", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Undervoltage Trip Level", $ Data Name "%", $ Units "Undervoltage Trip Level", $ Help String 50,99,65, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param147 = $ C: 0x93, I: 0x01, A: 0x0C - Protection UnderVoltage Trip Debounce 0, $ First field shall equal 0 6,"20 93 24 01 30 0C", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Undervoltage Debounce",$ Data Name "cycles", $ Units "Undervoltage Debounce",$ Help String 1,60,10, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param148 = $ C: 0x93, I: 0x01, A: 0x0D - Protection UnderVoltage Alarm Level 0, $ First field shall equal 0 6,"20 93 24 01 30 0D", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Undervoltage Alarm Level", $ Data Name "%", $ Units "Undervoltage Alarm Level", $ Help String 50,99,75, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param149 = $ C: 0x93, I: 0x01, A: 0x0F - Protection OverVoltage Trip Level 0, $ First field shall equal 0 6,"20 93 24 01 30 0F", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Overvoltage Trip Level", $ Data Name "%", $ Units "Overvoltage Trip Level", $ Help String 105,150,120, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param150 = $ C: 0x93, I: 0x01, A: 0x10 - Protection OverVoltage Trip Debounce 0, $ First field shall equal 0 6,"20 93 24 01 30 10", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Overvoltage Debounce", $ Data Name "cycles", $ Units "Overvoltage Debounce", $ Help String 1,60,5, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param151 = $ C: 0x93, I: 0x01, A: 0x11 - Protection OverVoltage Alarm Level 0, $ First field shall equal 0 6,"20 93 24 01 30 11", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Overvoltage Alarm Level", $ Data Name "%", $ Units "Overvoltage Alarm Level", $ Help String 105,150,120, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param152 = $ C: 0x9B, I: 0x01, A: 0x01 - Rated Voltage 0, $ First field shall equal 0 6,"20 9B 24 01 30 01", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Motor Rated Voltage", $ Data Name "V", $ Units "Motor Rated Voltage", $ Help String 2000,13800,4160, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param153 = $ C: 0x9B, I: 0x01, A: 0x02 - Motor Rated Hp Motor1 (Scaled by 100) 0, $ First field shall equal 0 6,"20 9B 24 01 30 02", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Motor Rated HP", $ Data Name "HP", $ Units "Motor Rated HP", $ Help String 100,10000,2795, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param154 = $ C: 0x9B, I: 0x01, A: 0x04 - Motor Rated Watts Motor1 0, $ First field shall equal 0 6,"20 9B 24 01 30 04", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Motor Rated Watts", $ Data Name "KW", $ Units "Motor Rated Watts", $ Help String 75,7450,2082, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param155 = $ C: 0x9B, I: 0x01, A: 0x06 - Motor Rated Speed Motor1 0, $ First field shall equal 0 6,"20 9B 24 01 30 06", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Motor Rated Speed", $ Data Name "rpm", $ Units "Motor Rated Speed", $ Help String 300,3600,1782, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param156 = $ C: 0x9B, I: 0x01, A: 0x08 - Rated Freq 0, $ First field shall equal 0 6,"20 9B 24 01 30 08", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Motor Rated Frequency",$ Data Name "Hz", $ Units "Motor Rated Frequency",$ Help String 50,60,60, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param157 = $ C: 0x9B, I: 0x01, A: 0x09 - Motor Rated Efficiency 0, $ First field shall equal 0 6,"20 9B 24 01 30 09", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Rated Efficiency x 100", $ Data Name "%", $ Units "Rated Efficiency x 100", $ Help String 5000,10000,9600, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param158 = $ C: 0x9B, I: 0x01, A: 0x0A - Motor Rated PF (scaled by 100) 0, $ First field shall equal 0 6,"20 9B 24 01 30 0A", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC3, $ Data Type 2, $ Data Size in Bytes "Motor Rated PF x 100", $ Data Name "", $ Units "Motor Rated PF x 100", $ Help String 5000,10000,8900, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param159 = $ C: 0x9B, I: 0x01, A: 0x0B - Motor Rated Service Factor 0, $ First field shall equal 0 6,"20 9B 24 01 30 0B", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Motor Rated Service Factor", $ Data Name "", $ Units "Motor Rated Service Factor", $ Help String 100,115,100, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param163 = $ C: 0x9B, I: 0x01, A: 0x65 - Motor Nominal Current FLA 0, $ First field shall equal 0 6,"20 9B 24 01 30 65", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Motor Nominal Current FLA", $ Data Name "A", $ Units "Motor Nominal Current FLA", $ Help String 21,800,400, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param164 = $ C: 0x9F, I: 0x01, A: 0x0D - Base Control Module Local Source Selector 0, $ First field shall equal 0 6,"20 9F 24 01 30 0D", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Local motor control source", $ Data Name "", $ Units "Local motor control source", $ Help String 0,2,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param165 = $ C: 0x9F, I: 0x01, A: 0x0E - Base Control Module Remote Source Selector 0, $ First field shall equal 0 6,"20 9F 24 01 30 0E", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Remote Control Source Select", $ Data Name "", $ Units "Remote Control Source Select", $ Help String 0,2,1, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param166 = $ C: 0x9F, I: 0x01, A: 0x0F - Base Control Module Local/Remote Power up mode 0, $ First field shall equal 0 6,"20 9F 24 01 30 0F", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Local/Remote power up mode", $ Data Name "", $ Units "Local/Remote power up mode", $ Help String 0,2,2, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param168 = $ C: 0xA0, I: 0x01, A: 0x01 - Remote Modbus Address 0, $ First field shall equal 0 6,"20 A0 24 01 30 01", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Base Control Module Modbus Port Address", $ Data Name "", $ Units "Base Control Module Modbus Port Address", $ Help String 1,247,1, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param169 = $ C: 0xA0, I: 0x01, A: 0x02 - Remote Modbus Baud Rate 0, $ First field shall equal 0 6,"20 A0 24 01 30 02", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Base Control Module Modbus port Baud Rate ID", $ Data Name "", $ Units "Base Control Module Modbus port Baud Rate ID", $ Help String 0,4,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param170 = $ C: 0xA0, I: 0x01, A: 0x03 - Remote Modbus Parity and Stop Bits 0, $ First field shall equal 0 6,"20 A0 24 01 30 03", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Base Control Module Modbus port Parity and Stop Bits", $ Data Name "", $ Units "Base Control Module Modbus port Parity and Stop Bits", $ Help String 0,5,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param171 = $ C: 0xA0, I: 0x01, A: 0x04 - Remote Modbus TX Mode 0, $ First field shall equal 0 6,"20 A0 24 01 30 04", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Base Control Module Modbus port TX mode", $ Data Name "", $ Units "Base Control Module Modbus port TX mode", $ Help String 0,1,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param172 = $ C: 0xA0, I: 0x01, A: 0x05 - Remote Modbus Communication Timeout 0, $ First field shall equal 0 6,"20 A0 24 01 30 05", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Base Control Module RS485 Modbus Timeout", $ Data Name "", $ Units "Base Control Module RS485 Modbus Timeout", $ Help String 0,0xFFFF,60000, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param173 = $ C: 0xA0, I: 0x01, A: 0x06 - Base Control Module USB Modbus CommTimeout 0, $ First field shall equal 0 6,"20 A0 24 01 30 06", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Base Control Module USB Modbus Timeout", $ Data Name "ms", $ Units "Base Control Module USB Modbus Timeout", $ Help String 0,0xFFFF,2000, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param174 = $ C: 0xA0, I: 0x01, A: 0x07 - User Interface USB Modbus CommTimeout 0, $ First field shall equal 0 6,"20 A0 24 01 30 07", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "User Interface USB Modbus Timeout", $ Data Name "ms", $ Units "User Interface USB Modbus Timeout", $ Help String 0,0xFFFF,10000, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param175 = $ C: 0xA1, I: 0x01, A: 0x01 - Motor State (enum) 0, $ First field shall equal 0 6,"20 A1 24 01 30 01", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Motor State", $ Data Name "", $ Units "Motor State", $ Help String 0,7,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param176 = $ C: 0xA1, I: 0x01, A: 0x07 - Number of Contactor Operations During Last Hour 0, $ First field shall equal 0 6,"20 A1 24 01 30 07", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Motor Starts During Last Hour", $ Data Name "", $ Units "Motor Starts During Last Hour", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param177 = $ C: 0xA1, I: 0x01, A: 0x08 - Number of Motor Starts User 0, $ First field shall equal 0 6,"20 A1 24 01 30 08", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC8, $ Data Type 4, $ Data Size in Bytes "Total Number of Starts (Resettable)", $ Data Name "", $ Units "Total Number of Starts (Resettable)", $ Help String 0,0xFFFFFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param178 = $ C: 0xA1, I: 0x01, A: 0x09 - Motor Run Time Total Reset 0, $ First field shall equal 0 6,"20 A1 24 01 30 09", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC8, $ Data Type 4, $ Data Size in Bytes "Total Motor Run Time (Resettable)", $ Data Name "ms", $ Units "Total Motor Run Time (Resettable)", $ Help String 0,0xFFFFFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !十进制位数Param179=C0xA1I0x01A0x0B-最后一次测量启动时间时间提高速度0, $ First field shall equal 0 6,"20 A1 24 01 30 0B", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Last Measured Starting Time", $ Data Name "seconds", $ Units "Last Measured Starting Time", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !十进制位数Param180=C0xA1I0x01A0x0C0, $ First field shall equal 0 6,"20 A1 24 01 30 0C", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC8, $ Data Type 4, $ Data Size in Bytes "Latest Run Time", $ Data Name "hr:min", $ Units "Latest Run Time", $ Help String 0,0xFFFFFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param181 = $ C: 0xA1, I: 0x01, A: 0x0F - Motor Max Starting Current - Scaled 0, $ First field shall equal 0 6,"20 A1 24 01 30 0F", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Maximum Start Current",$ Data Name "A", $ Units "Maximum Start Current",$ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param186 = $ C: 0xA1, I: 0x01, A: 0x15 - VA 0, $ First field shall equal 0 6,"20 A1 24 01 30 15", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Total VA", $ Data Name "KVA", $ Units "Total VA", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param187 = $ C: 0xA1, I: 0x01, A: 0x16 - VARS 0, $ First field shall equal 0 6,"20 A1 24 01 30 16", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC3, $ Data Type 2, $ Data Size in Bytes "Total VARS", $ Data Name "KVAR", $ Units "Total VARS", $ Help String 0x8000,0x7FFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param192 = $ C: 0xA1, I: 0x01, A: 0x65 - Time since the Last Start 0, $ First field shall equal 0 6,"20 A1 24 01 30 65", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC8, $ Data Type 4, $ Data Size in Bytes "Time since the Last Start", $ Data Name "seconds", $ Units "Time since the Last Start", $ Help String 0,0xFFFFFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param193 = $ C: 0xA2, I: 0x01, A: 0x0A - phase Order (user select ignore/ABC/ACB) 0, $ First field shall equal 0 6,"20 A2 24 01 30 0A", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "phase Order (ABC/ACB)",$ Data Name "", $ Units "phase Order (ABC/ACB)",$ Help String 1,2,1, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param194 = $ C: 0xA2, I: 0x01, A: 0x0B - Protection Instantaneous Overcurrent Trip Level 0, $ First field shall equal 0 6,"20 A2 24 01 30 0B", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Instantaneous Overcurrent Trip Level", $ Data Name "%FLA", $ Units "Instantaneous Overcurrent Trip Level", $ Help String 200,1000,800, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param195 = $ C: 0xA2, I: 0x01, A: 0x0C - Protection Instantaneous Overcurrent Debounce 0, $ First field shall equal 0 6,"20 A2 24 01 30 0C", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Instantaneous Overcurrent Debounce", $ Data Name "cycles", $ Units "Instantaneous Overcurrent Debounce", $ Help String 1,60,3, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param196 = $ C: 0xA2, I: 0x01, A: 0x0D - Protection Instantaneous Overcurrent Alarm Level 0, $ First field shall equal 0 6,"20 A2 24 01 30 0D", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Instantaneous Overcurrent Alarm Level", $ Data Name "%FLA", $ Units "Instantaneous Overcurrent Alarm Level", $ Help String 200,1000,700, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param198 = $ C: 0xA2, I: 0x01, A: 0x34 - Number of Starts per Hour allowed before trip 0, $ First field shall equal 0 6,"20 A2 24 01 30 34", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Allowed Starts Per Hour", $ Data Name "", $ Units "Allowed Starts Per Hour", $ Help String 1,10,4, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param200 = $ C: 0xA5, I: 0x01, A: 0x01 - Fault Snap Shot Log Year 0, $ First field shall equal 0 6,"20 A5 24 01 30 01", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Snap Shot Year", $ Data Name "", $ Units "Snap Shot Year", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param201 = $ C: 0xA5, I: 0x01, A: 0x02 - Fault Snap Shot Log Month 0, $ First field shall equal 0 6,"20 A5 24 01 30 02", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Snap Shot Month", $ Data Name "", $ Units "Snap Shot Month", $ Help String 0,0xFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param202 = $ C: 0xA5, I: 0x01, A: 0x03 - Fault Snap Shot Log Day 0, $ First field shall equal 0 6,"20 A5 24 01 30 03", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Snap Shot Day", $ Data Name "", $ Units "Snap Shot Day", $ Help String 0,0xFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param203 = $ C: 0xA5, I: 0x01, A: 0x04 - Fault Snap Shot Log Hour 0, $ First field shall equal 0 6,"20 A5 24 01 30 04", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Snap Shot Hour", $ Data Name "hour", $ Units "Snap Shot Hour", $ Help String 0,0xFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param204 = $ C: 0xA5, I: 0x01, A: 0x05 - Fault Snap Shot Log Minute 0, $ First field shall equal 0 6,"20 A5 24 01 30 05", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Snap Shot Minute", $ Data Name "minutes", $ Units "Snap Shot Minute", $ Help String 0,0xFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param205 = $ C: 0xA5, I: 0x01, A: 0x06 - Fault Snap Shot Log Second 0, $ First field shall equal 0 6,"20 A5 24 01 30 06", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Snap Shot Second", $ Data Name "seconds", $ Units "Snap Shot Second", $ Help String 0,0xFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param206 = $ C: 0xA5, I: 0x01, A: 0x07 - Fault Snap Shot Trip Reason 0, $ First field shall equal 0 6,"20 A5 24 01 30 07", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Snap Shot Trip Reason",$ Data Name "", $ Units "Snap Shot Trip Reason",$ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param207 = $ C: 0xA5, I: 0x01, A: 0x08 - Fault Snap Shot Log TP 0, $ First field shall equal 0 6,"20 A5 24 01 30 08", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Snap Shot Thermal Capacity", $ Data Name "%", $ Units "Snap Shot Thermal Capacity", $ Help String 0,0xFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param208 = $ C: 0xA5, I: 0x01, A: 0x09 - Fault Snap Shot Log Ia 0, $ First field shall equal 0 6,"20 A5 24 01 30 09", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Snap Shot I Phase A (L1)", $ Data Name "A", $ Units "Snap Shot I Phase A (L1)", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param209 = $ C: 0xA5, I: 0x01, A: 0x0A - Fault Snap Shot Log Ib 0, $ First field shall equal 0 6,"20 A5 24 01 30 0A", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Snap Shot I Phase B (L2)", $ Data Name "A", $ Units "Snap Shot I Phase B (L2)", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param210 = $ C: 0xA5, I: 0x01, A: 0x0B - Fault Snap Shot Log Ic 0, $ First field shall equal 0 6,"20 A5 24 01 30 0B", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Snap Shot I Phase C (L3)", $ Data Name "A", $ Units "Snap Shot I Phase C (L3)", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param211 = $ C: 0xA5, I: 0x01, A: 0x0C - Fault Snap Shot Log Vab 0, $ First field shall equal 0 6,"20 A5 24 01 30 0C", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Snap Shot Voltage L1-L2", $ Data Name "V", $ Units "Snap Shot Voltage L1-L2", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param212 = $ C: 0xA5, I: 0x01, A: 0x0D - Fault Snap Shot Log Vbc 0, $ First field shall equal 0 6,"20 A5 24 01 30 0D", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Snap Shot Voltage L2-L3", $ Data Name "V", $ Units "Snap Shot Voltage L2-L3", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param213 = $ C: 0xA5, I: 0x01, A: 0x0E - Fault Snap Shot Log Vca 0, $ First field shall equal 0 6,"20 A5 24 01 30 0E", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Snap Shot Voltage L3-L1", $ Data Name "V", $ Units "Snap Shot Voltage L3-L1", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param214 = $ C: 0xA5, I: 0x01, A: 0x0F - Fault Snap Shot Log Frequency 0, $ First field shall equal 0 6,"20 A5 24 01 30 0F", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Snap Shot Frequency x 100", $ Data Name "Hz", $ Units "Snap Shot Frequency x 100", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param215 = $ C: 0xA5, I: 0x01, A: 0x10 - Fault Snap Shot Log Real Power (watts) 0, $ First field shall equal 0 6,"20 A5 24 01 30 10", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC8, $ Data Type 4, $ Data Size in Bytes "Snap Shot Watts", $ Data Name "KW", $ Units "Snap Shot Watts", $ Help String 0,0xFFFFFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param216 = $ C: 0xA5, I: 0x01, A: 0x11 - Fault Snap Shot Log Apparent Power (VA) 0, $ First field shall equal 0 6,"20 A5 24 01 30 11", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC8, $ Data Type 4, $ Data Size in Bytes "Snap Shot VA ", $ Data Name "KVA", $ Units "Snap Shot VA ", $ Help String 0,0xFFFFFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param217 = $ C: 0xA5, I: 0x01, A: 0x12 - Fault Snap Shot Log Power Factor 0, $ First field shall equal 0 6,"20 A5 24 01 30 12", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Snap Shot Power Factor x 100", $ Data Name "%", $ Units "Snap Shot Power Factor x 100", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param218 = $ C: 0xAA, I: 0x01, A: 0x01 - Set Admin Password 0, $ First field shall equal 0 6,"20 AA 24 01 30 01", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC8, $ Data Type 4, $ Data Size in Bytes "Set Admin Password", $ Data Name "", $ Units "Set Admin Password", $ Help String 0,0xFFFFFFFF,0x00000000,$ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param219 = $ C: 0xAA, I: 0x01, A: 0x02 - Admin Login 0, $ First field shall equal 0 6,"20 AA 24 01 30 02", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC8, $ Data Type 4, $ Data Size in Bytes "Administrator Login", $ Data Name "", $ Units "Administrator Login", $ Help String 0,0xFFFFFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param222 = $ C: 0xAA, I: 0x01, A: 0x05 - Motor Running Parameter Lock Override 0, $ First field shall equal 0 6,"20 AA 24 01 30 05", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC1, $ Data Type 1, $ Data Size in Bytes "Motor Run Parameter Lock Override", $ Data Name "", $ Units "Motor Run Parameter Lock Override", $ Help String 0,1,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param223 = $ C: 0xAA, I: 0x01, A: 0x06 - Motor Running Parameter Lock 0, $ First field shall equal 0 6,"20 AA 24 01 30 06", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Motor Running Parameter Access Lock", $ Data Name "", $ Units "Motor Running Parameter Access Lock", $ Help String 0,0xFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param224 = $ C: 0xAA, I: 0x01, A: 0x07 - Password Parameter Lock 0, $ First field shall equal 0 6,"20 AA 24 01 30 07", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Param Lock", $ Data Name "", $ Units "Param Lock", $ Help String 0,0xFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param226 = $ C: 0xAA, I: 0x01, A: 0x09 - Set Manufacturing Password 0, $ First field shall equal 0 6,"20 AA 24 01 30 09", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC8, $ Data Type 4, $ Data Size in Bytes "Set Manufacturing Password", $ Data Name "", $ Units "Set Manufacturing Password", $ Help String 0,0xFFFFFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param227 = $ C: 0xAA, I: 0x01, A: 0x0A - Manufacturing Login 0, $ First field shall equal 0 6,"20 AA 24 01 30 0A", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC8, $ Data Type 4, $ Data Size in Bytes "Manufacturing Login", $ Data Name "", $ Units "Manufacturing Login", $ Help String 0,0xFFFFFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param228 = $ C: 0xB0, I: 0x01, A: 0x01 - RTC Time 0, $ First field shall equal 0 6,"20 B0 24 01 30 01", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "RTC Time", $ Data Name "", $ Units "RTC Time", $ Help String 0,0xFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param229 = $ C: 0xB0, I: 0x01, A: 0x02 - RTC Year 0, $ First field shall equal 0 6,"20 B0 24 01 30 02", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "RTC Year", $ Data Name "", $ Units "RTC Year", $ Help String 2000,2200,2000, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param230 = $ C: 0xB0, I: 0x01, A: 0x03 - RTC Month 0, $ First field shall equal 0 6,"20 B0 24 01 30 03", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "RTC Month", $ Data Name "", $ Units "RTC Month", $ Help String 1,12,1, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param231 = $ C: 0xB0, I: 0x01, A: 0x04 - RTC Day of Month 0, $ First field shall equal 0 6,"20 B0 24 01 30 04", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "RTC Day of Month", $ Data Name "", $ Units "RTC Day of Month", $ Help String 1,31,1, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param232 = $ C: 0xB0, I: 0x01, A: 0x09 - RTC Time Zone Hours and Minutes 0, $ First field shall equal 0 6,"20 B0 24 01 30 09", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "RTC Time Zone hh mm", $ Data Name "", $ Units "RTC Time Zone hh mm", $ Help String 0,0xFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param233 = $ C: 0xB0, I: 0x01, A: 0x0A - RTC Time Zone Ahead of UTC 0, $ First field shall equal 0 6,"20 B0 24 01 30 0A", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "RTC Time Zone Ahead of UTC", $ Data Name "", $ Units "RTC Time Zone Ahead of UTC", $ Help String 0,1,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param234 = $ C: 0xB0, I: 0x01, A: 0x0C - RTC DST Rule 0, $ First field shall equal 0 6,"20 B0 24 01 30 0C", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "RTC DST Rule", $ Data Name "", $ Units "RTC DST Rule", $ Help String 0,7,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param235 = $ C: 0xB0, I: 0x01, A: 0x0D - RTC Manual DST Rule Start Time 0, $ First field shall equal 0 6,"20 B0 24 01 30 0D", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "RTC Manual DST Rule Start", $ Data Name "", $ Units "RTC Manual DST Rule Start", $ Help String 0,0xFF,3, $ Min Value $ Max Value $ The default is really a string of but due to the EDS interpreter limitation we included only the first value to avoid errors ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param236 = $ C: 0xB0, I: 0x01, A: 0x0E - RTC Manual DST Rule End Time 0, $ First field shall equal 0 6,"20 B0 24 01 30 0E", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "RTC Manual DST Rule End", $ Data Name "", $ Units "RTC Manual DST Rule End", $ Help String 0,0xFF,11, $ Min Value $ Max Value $ The default is really a string of but due to the EDS interpreter limitation we included only the first value to avoid errors ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param237 = $ C: 0xB0, I: 0x01, A: 0x10 - RTC Time Hours 0, $ First field shall equal 0 6,"20 B0 24 01 30 10", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "RTC Time hours", $ Data Name "hours", $ Units "RTC Time hours", $ Help String 0,23,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param238 = $ C: 0xB0, I: 0x01, A: 0x11 - RTC Time Minutes 0, $ First field shall equal 0 6,"20 B0 24 01 30 11", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "RTC Time minutes", $ Data Name "minutes", $ Units "RTC Time minutes", $ Help String 0,59,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param239 = $ C: 0xB0, I: 0x01, A: 0x12 - RTC Time Seconds 0, $ First field shall equal 0 6,"20 B0 24 01 30 12", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0020, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "RTC Time seconds", $ Data Name "seconds", $ Units "RTC Time seconds", $ Help String 0,59,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param240 = $ C: 0xB0, I: 0x01, A: 0x13 - RTC Time 0, $ First field shall equal 0 6,"20 B0 24 01 30 13", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "RTC Time milliseconds",$ Data Name "ms", $ Units "RTC Time milliseconds",$ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param241 = $ C: 0xB1, I: 0x01, A: 0x01 - Base Control Module DIP Switches 0, $ First field shall equal 0 6,"20 B1 24 01 30 01", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xD2, $ Data Type 2, $ Data Size in Bytes "Base Control Module Dip Switches", $ Data Name "", $ Units "Base Control Module Dip Switches", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param242 = $ C: 0xB1, I: 0x01, A: 0x02 - Base Control Module Control Voltage (24VDC) 0, $ First field shall equal 0 6,"20 B1 24 01 30 02", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Base Control Module Control Voltage", $ Data Name "", $ Units "Base Control Module Control Voltage", $ Help String 0,0xFFFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param310 = $ C: 0xB3, I: 0x01, A: 0x01 - Modbus Comm Loss Timeout Value (ms) 0, $ First field shall equal 0 6,"20 B3 24 01 30 01", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Modbus TCP Com Timeout", $ Data Name "", $ Units "Modbus TCP Com Timeout", $ Help String 0,0xFFFF,2000, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param312 = $ C: 0xB3, I: 0x01, A: 0x03 - Master Key for Hardcoded IP Address Selection 0, $ First field shall equal 0 6,"20 B3 24 01 30 03", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC1, $ Data Type 1, $ Data Size in Bytes "Master Key for Hardcoded IP Address Selection", $ Data Name "", $ Units "Master Key for Hardcoded IP Address Selection", $ Help String 0,1,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param313 = $ C: 0xB3, I: 0x01, A: 0x04 - Active IP Address 0, $ First field shall equal 0 6,"20 B3 24 01 30 04", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Present Ethernet IP Address", $ Data Name "", $ Units "Present Ethernet IP Address", $ Help String 0,0xFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param314 = $ C: 0xB3, I: 0x01, A: 0x05 - Active Subnet Mask 0, $ First field shall equal 0 6,"20 B3 24 01 30 05", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Present Ethernet Subnet Mask", $ Data Name "", $ Units "Present Ethernet Subnet Mask", $ Help String 0,0xFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param315 = $ C: 0xB3, I: 0x01, A: 0x06 - Active Default Gateway 0, $ First field shall equal 0 6,"20 B3 24 01 30 06", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Present Ethernet Default Gateway", $ Data Name "", $ Units "Present Ethernet Default Gateway", $ Help String 0,0xFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param316 = $ C: 0xB3, I: 0x01, A: 0x07 - Static IP Address 0, $ First field shall equal 0 6,"20 B3 24 01 30 07", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Stored Ethernet IP Address", $ Data Name "", $ Units "Stored Ethernet IP Address", $ Help String 0,0xFF,0xFE, $ Min Value $ Max Value $ The default is really a string of but due to the EDS interpreter limitation we included only the first value to avoid errors ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param317 = $ C: 0xB3, I: 0x01, A: 0x08 - Static Subnet Mask 0, $ First field shall equal 0 6,"20 B3 24 01 30 08", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Stored Ethernet Subnet Mask", $ Data Name "", $ Units "Stored Ethernet Subnet Mask", $ Help String 0,0xFF,0x00, $ Min Value $ Max Value $ The default is really a string of but due to the EDS interpreter limitation we included only the first value to avoid errors ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param318 = $ C: 0xB3, I: 0x01, A: 0x09 - Static Default Gateway 0, $ First field shall equal 0 6,"20 B3 24 01 30 09", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Stored Ethernet Default Gateway", $ Data Name "", $ Units "Stored Ethernet Default Gateway", $ Help String 0,0xFF,0x01, $ Min Value $ Max Value $ The default is really a string of but due to the EDS interpreter limitation we included only the first value to avoid errors ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param319 = $ C: 0xB3, I: 0x01, A: 0x0A - Ethernet PHY 1 - Link Speed Select 0, $ First field shall equal 0 6,"20 B3 24 01 30 0A", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Ethernet Port 1 Speed Select", $ Data Name "", $ Units "Ethernet Port 1 Speed Select", $ Help String 10,100,100, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param320 = $ C: 0xB3, I: 0x01, A: 0x0B - Ethernet PHY 1 - Link Speed Actual 0, $ First field shall equal 0 6,"20 B3 24 01 30 0B", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Ethernet Port 1 Speed Actual", $ Data Name "", $ Units "Ethernet Port 1 Speed Actual", $ Help String 10,100,10, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param321 = $ C: 0xB3, I: 0x01, A: 0x0C - Ethernet PHY 1 - Duplex Select 0, $ First field shall equal 0 6,"20 B3 24 01 30 0C", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC1, $ Data Type 1, $ Data Size in Bytes "Ethernet Port 1 Full Duplex Enable", $ Data Name "", $ Units "Ethernet Port 1 Full Duplex Enable", $ Help String 0,1,1, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param322 = $ C: 0xB3, I: 0x01, A: 0x0D - Ethernet PHY 1 - Duplex Actual 0, $ First field shall equal 0 6,"20 B3 24 01 30 0D", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC1, $ Data Type 1, $ Data Size in Bytes "Ethernet Port 1 Full Duplex Enabled", $ Data Name "", $ Units "Ethernet Port 1 Full Duplex Enabled", $ Help String 0,1,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param323 = $ C: 0xB3, I: 0x01, A: 0x0E - Ethernet PHY 1 - Link Auto-Negotiate Enable 0, $ First field shall equal 0 6,"20 B3 24 01 30 0E", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC1, $ Data Type 1, $ Data Size in Bytes "Ethernet Port 1 Autonegotiate Enable", $ Data Name "", $ Units "Ethernet Port 1 Autonegotiate Enable", $ Help String 0,1,1, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param324 = $ C: 0xB3, I: 0x01, A: 0x0F - Ethernet PHY 1 - Link Auto-Negotiate State 0, $ First field shall equal 0 6,"20 B3 24 01 30 0F", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Ethernet Port 1 Autonegotiate State", $ Data Name "", $ Units "Ethernet Port 1 Autonegotiate State", $ Help String 0,6,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param325 = $ C: 0xB3, I: 0x01, A: 0x10 - Ethernet PHY 1 - Port Enable 0, $ First field shall equal 0 6,"20 B3 24 01 30 10", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC1, $ Data Type 1, $ Data Size in Bytes "Ethernet Port 1 Enabled", $ Data Name "", $ Units "Ethernet Port 1 Enabled", $ Help String 0,1,1, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param326 = $ C: 0xB3, I: 0x01, A: 0x11 - Ethernet PHY 2 - Link Speed Select 0, $ First field shall equal 0 6,"20 B3 24 01 30 11", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Ethernet Port 2 Speed Select", $ Data Name "", $ Units "Ethernet Port 2 Speed Select", $ Help String 10,100,100, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param327 = $ C: 0xB3, I: 0x01, A: 0x12 - Ethernet PHY 2 - Link Speed Actual 0, $ First field shall equal 0 6,"20 B3 24 01 30 12", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC7, $ Data Type 2, $ Data Size in Bytes "Ethernet Port 2 Speed Actual", $ Data Name "", $ Units "Ethernet Port 2 Speed Actual", $ Help String 10,100,10, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param328 = $ C: 0xB3, I: 0x01, A: 0x13 - Ethernet PHY 2 - Duplex Select 0, $ First field shall equal 0 6,"20 B3 24 01 30 13", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC1, $ Data Type 1, $ Data Size in Bytes "Ethernet Port 2 Full Duplex Enable", $ Data Name "", $ Units "Ethernet Port 2 Full Duplex Enable", $ Help String 0,1,1, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param329 = $ C: 0xB3, I: 0x01, A: 0x14 - Ethernet PHY 2 - Duplex Actual 0, $ First field shall equal 0 6,"20 B3 24 01 30 14", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC1, $ Data Type 1, $ Data Size in Bytes "Ethernet Port 2 Full Duplex Enabled", $ Data Name "", $ Units "Ethernet Port 2 Full Duplex Enabled", $ Help String 0,1,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param330 = $ C: 0xB3, I: 0x01, A: 0x15 - Ethernet PHY 2 - Link Auto-Negotiate Enable 0, $ First field shall equal 0 6,"20 B3 24 01 30 15", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC1, $ Data Type 1, $ Data Size in Bytes "Ethernet Port 2 Autonegotiate Enabled", $ Data Name "", $ Units "Ethernet Port 2 Autonegotiate Enabled", $ Help String 0,1,1, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param331 = $ C: 0xB3, I: 0x01, A: 0x16 - Ethernet PHY 2 - Link Auto-Negotiate State 0, $ First field shall equal 0 6,"20 B3 24 01 30 16", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Ethernet Port 2 Autonegotiate State", $ Data Name "", $ Units "Ethernet Port 2 Autonegotiate State", $ Help String 0,6,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param332 = $ C: 0xB3, I: 0x01, A: 0x17 - Ethernet PHY 2 - Port Enable 0, $ First field shall equal 0 6,"20 B3 24 01 30 17", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC1, $ Data Type 1, $ Data Size in Bytes "Ethernet Port 2 Enabled", $ Data Name "", $ Units "Ethernet Port 2 Enabled", $ Help String 0,1,1, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param333 = $ C: 0xB3, I: 0x01, A: 0x18 - ACD Enable 0, $ First field shall equal 0 6,"20 B3 24 01 30 18", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC1, $ Data Type 1, $ Data Size in Bytes "Address Conflict Detection Enable", $ Data Name "", $ Units "Address Conflict Detection Enable", $ Help String 0,1,1, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param334 = $ C: 0xB3, I: 0x01, A: 0x19 - ACD Conflict State 0, $ First field shall equal 0 6,"20 B3 24 01 30 19", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Address Conflict Detection Status", $ Data Name "", $ Units "Address Conflict Detection Status", $ Help String 0,3,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param335 = $ C: 0xB3, I: 0x01, A: 0x1A - ACD Conflicted State 0, $ First field shall equal 0 6,"20 B3 24 01 30 1A", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Address Conflict Detection Conflicted Status", $ Data Name "", $ Units "Address Conflict Detection Conflicted Status", $ Help String 0,0,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param336 = $ C: 0xB3, I: 0x01, A: 0x1B - ACD Conflicted Device MAC 0, $ First field shall equal 0 6,"20 B3 24 01 30 1B", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0000, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Address Conflict Detection Conflicted MAC", $ Data Name "", $ Units "Address Conflict Detection Conflicted MAC", $ Help String 0,0,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places Param337 = $ C: 0xB3, I: 0x01, A: 0x1C - Ethernet MAC Address 0, $ First field shall equal 0 6,"20 B3 24 01 30 1C", $ Link Path Size, Link Path (Class, Inst, Attrib) 0x0030, $ Descriptor Bits 0xC6, $ Data Type 1, $ Data Size in Bytes "Ethernet MAC Address", $ Data Name "", $ Units "Ethernet MAC Address", $ Help String 0,0xFF,0, $ Min Value $ Max Value $ Default Value ,,,, $ Mult, Div, Base, Offset Scaling ,,,, $ Mult, Div, Base, Offset Links !$ Decimal Places [Groups] Group1 = $ C: 0x29 - Control Supervisor "Control Supervisor", $ Class Description 17, $ Class Attribute Count 43,44,45,46,47,48,49,50,51,54, 55,56,57,35,36,52,53!$ Class Attribute List $ Class Attribute List $ Class Attribute List $ Class Attribute List $ Class Attribute List Group2 = $ C: 0x2C - Overload "Overload", $ Class Description 21, $ Class Attribute Count 65,66,68,69,70,71,72,74,75,76, 77,78,79,80,81,37,25,17,18,19, 2!$ Class Attribute List $ Class Attribute List $ Class Attribute List $ Class Attribute List $ Class Attribute List $ Class Attribute List Group3 = $ C: 0x2D - Soft Start "Soft Start ", $ Class Description 34, $ Class Attribute Count 82,83,85,86,87,88,89,90,91,92, 93,94,95,96,97,98,99,100,103,104, 105,106,107,108,109,110,111,112,113,114, 115,116,117,3!$ Class Attribute List $ Class Attribute List $ Class Attribute List $ Class Attribute List $ Class Attribute List $ Class Attribute List $ Class Attribute List $ Class Attribute List $ Class Attribute List Group4 = $ C: 0x88 - System Component Definition "System Component Definition", $ Class Description 20, $ Class Attribute Count 118,119,120,121,122,123,124,125,126,127, 128,129,130,131,132,133,134,135,136,137!$ Class Attribute List $ Class Attribute List $ Class Attribute List $ Class Attribute List $ Class Attribute List Group5 = $ C: 0x93 - Voltage Object "Voltage Object", $ Class Description 14, $ Class Attribute Count 142,143,145,146,147,148,149,150,151,26, 27,28,29,34!$ Class Attribute List $ Class Attribute List $ Class Attribute List $ Class Attribute List Group6 = $ C: 0x9B - Motor Info "Motor Info", $ Class Description 9, $ Class Attribute Count 152,153,154,155,156,157,158,159,163!$ Class Attribute List $ Class Attribute List $ Class Attribute List Group7 = $ C: 0x9F - Operation Mode "Operation Mode", $ Class Description 3, $ Class Attribute Count 164,165,166!$ Class Attribute List Group8 = $ C: 0xA0 - Modbus "Modbus", $ Class Description 7, $ Class Attribute Count 168,169,170,171,172,173,174!$ Class Attribute List $ Class Attribute List Group9 = $ C: 0xA1 - Motor Monitoring "Motor Monitoring", $ Class Description 12, $ Class Attribute Count 175,176,177,178,179,180,181,186,187,192, 30,33!$ Class Attribute List $ Class Attribute List $ Class Attribute List $ Class Attribute List $ Class Attribute List Group10 = $ C: 0xA2 - Motor Protection "Motor Protection", $ Class Description 5, $ Class Attribute Count 193,194,195,196,198!$ Class Attribute List $ Class Attribute List Group11 = $ C: 0xA5 - Snap Shot "Snap Shot", $ Class Description 18, $ Class Attribute Count 200,201,202,203,204,205,206,207,208,209, 210,211,212,213,214,215,216,217!$ Class Attribute List $ Class Attribute List $ Class Attribute List $ Class Attribute List $ Class Attribute List Group12 = $ C: 0xAA - Parameter Access "Parameter Access", $ Class Description 7, $ Class Attribute Count 218,219,222,223,224,226,227!$ Class Attribute List $ Class Attribute List $ Class Attribute List Group13 = $ C: 0xB0 - RTC "RTC", $ Class Description 13, $ Class Attribute Count 228,229,230,231,232,233,234,235,236,237, 238,239,240!$ Class Attribute List $ Class Attribute List $ Class Attribute List $ Class Attribute List Group14 = $ C: 0xB1 - BCM "BCM", $ Class Description 2, $ Class Attribute Count 241,242!$ Class Attribute List Group15 = $ C: 0xB3 - Option Card "Option Card", $ Class Description 27, $ Class Attribute Count 310,312,313,314,315,316,317,318,319,320, 321,322,323,324,325,326,327,328,329,330, 331,332,333,334,335,336,337!$ Class Attribute List $ Class Attribute List $ Class Attribute List $ Class Attribute List $ Class Attribute List $ Class Attribute List $ Class Attribute List [Assembly] MaxInst = 150!数表Satistic#Instances=15最大数_Of_Dynic_Instances=1Class_Attributes = 1, 2, 3, 4, 6, 7!实例分配s+3+4services=0x0E0x08实例_Services=0x0E0x100x18Assem3 = $ Assembly Instance #:3 (03) - Assembly "Basic Motor Starter o/p assembly", $ Data Name "20 04 24 03 30 03", $ Path 1, $ Data Size (in bytes) 0x0000, $ Descriptor ,, $ Reserved - Must Be Empty 8,Param12!$ Member Size (in bits), Member Reference Assem60 = $ Assembly Instance #:60 (3C) - Assembly "Basic Motor Starter I/p status word assembly", $ Data Name "20 04 24 3C 30 03", $ Path 1, $ Data Size (in bytes) 0x0000, $ Descriptor ,, $ Reserved - Must Be Empty 8,Param13!$ Member Size (in bits), Member Reference Assem61 = $ Assembly Instance #:61 (3D) - Assembly "Basic Motor Starter I/p status word assembly", $ Data Name "20 04 24 3D 30 03", $ Path 1, $ Data Size (in bytes) 0x0000, $ Descriptor ,, $ Reserved - Must Be Empty 8,Param14!$ Member Size (in bits), Member Reference Assem100 = $ Assembly Instance #:100 (64) - Assembly "Status and Current", $ Data Name "20 04 24 64 30 03", $ Path 8, $ Data Size (in bytes) 0x0000, $ Descriptor ,, $ Reserved - Must Be Empty 16,Param16, $ Member Size (in bits), Member Reference 16,Param17, $ Member Size (in bits), Member Reference 16,Param18, $ Member Size (in bits), Member Reference 16,Param19!$ Member Size (in bits), Member Reference Assem101 = $ Assembly Instance #:101 (65) - Assembly "Status and Current and Remote Inputs", $ Data Name "20 04 24 65 30 03", $ Path 37, $ Data Size (in bytes) 0x0000, $ Descriptor ,, $ Reserved - Must Be Empty 16,Param16, $ Member Size (in bits), Member Reference 16,Param17, $ Member Size (in bits), Member Reference 16,Param18, $ Member Size (in bits), Member Reference 16,Param19, $ Member Size (in bits), Member Reference 16,Param25, $ Member Size (in bits), Member Reference 16,Param26, $ Member Size (in bits), Member Reference 16,Param27, $ Member Size (in bits), Member Reference 16,Param28, $ Member Size (in bits), Member Reference 16,Param29, $ Member Size (in bits), Member Reference 16,Param30, $ Member Size (in bits), Member Reference 16,Param31, $ Member Size (in bits), Member Reference 16,Param32, $ Member Size (in bits), Member Reference 16,Param33, $ Member Size (in bits), Member Reference 16,Param34, $ Member Size (in bits), Member Reference 32,Param35, $ Member Size (in bits), Member Reference 32,Param36, $ Member Size (in bits), Member Reference 8,Param37!$ Member Size (in bits), Member Reference Assem102 = $ Assembly Instance #:102 (66) - Assembly "Status and Current and Remote Inputs", $ Data Name "20 04 24 66 30 03", $ Path 10, $ Data Size (in bytes) 0x0000, $ Descriptor ,, $ Reserved - Must Be Empty 16,Param16, $ Member Size (in bits), Member Reference 16,Param25, $ Member Size (in bits), Member Reference 16,Param29, $ Member Size (in bits), Member Reference 32,Param35!成员大小分解Object_Name=Cunction管理对象Object_Class_Code=0x06MaxInst=5数表Satistic#Instances=5最大数_Of_Dynic_Instances=0Class_Attributes = 1, 2, 3, 4, 6, 7!Instance_Attributes = 1, 2, 3, 4, 5, 6, 7, 8!services=0x01x0EInstance_Services = 0x01, 0x02, 0x0E, 0x10, 0x54, 0x5B, 0x4E, 0x52, 0x5A!Connection1 = 0x04010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = application type: listen-only $ 25 = application type: input-only $ 26 = application type: exclusive-owner $ 27 = application type: redundant-owner $ 28-30 = reserved $ 31 = Direction: Client = 0 / Server = 1 0x44640405, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved Param1,,Assem3, $ O->T RPI, size, format Param1,,Assem60, $ T->O RPI, size, format ,, $ proxy config size, format ,, $ target config size, format "Asm 3 OT - 60 TO", $ Connection Name "", $ help string "20 04 24 01 2C 03 2C 3C"!$ Path Connection2 = 0x04010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = application type: listen-only $ 25 = application type: input-only $ 26 = application type: exclusive-owner $ 27 = application type: redundant-owner $ 28-30 = reserved $ 31 = Direction: Client = 0 / Server = 1 0x44640405, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved Param1,,Assem3, $ O->T RPI, size, format Param1,,Assem61, $ T->O RPI, size, format ,, $ proxy config size, format ,, $ target config size, format "Asm 3 OT - 61 TO", $ Connection Name "", $ help string "20 04 24 01 2C 03 2C 3D"!$ Path Connection3 = 0x04010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = application type: listen-only $ 25 = application type: input-only $ 26 = application type: exclusive-owner $ 27 = application type: redundant-owner $ 28-30 = reserved $ 31 = Direction: Client = 0 / Server = 1 0x44640405, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved Param1,,Assem3, $ O->T RPI, size, format Param1,,Assem100, $ T->O RPI, size, format ,, $ proxy config size, format ,, $ target config size, format "Asm 3 OT - 100 TO", $ Connection Name "", $ help string "20 04 24 01 2C 03 2C 64"!$ Path Connection4 = 0x04010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = application type: listen-only $ 25 = application type: input-only $ 26 = application type: exclusive-owner $ 27 = application type: redundant-owner $ 28-30 = reserved $ 31 = Direction: Client = 0 / Server = 1 0x44640405, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved Param1,,Assem3, $ O->T RPI, size, format Param1,,Assem101, $ T->O RPI, size, format ,, $ proxy config size, format ,, $ target config size, format "Asm 3 OT - 101 TO", $ Connection Name "", $ help string "20 04 24 01 2C 03 2C 65"!$ Path Connection5 = 0x04010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = application type: listen-only $ 25 = application type: input-only $ 26 = application type: exclusive-owner $ 27 = application type: redundant-owner $ 28-30 = reserved $ 31 = Direction: Client = 0 / Server = 1 0x44640405, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved Param1,,Assem3, $ O->T RPI, size, format Param1,,Assem102, $ T->O RPI, size, format ,, $ proxy config size, format ,, $ target config size, format "Asm 3 OT - 102 TO", $ Connection Name "", $ help string "20 04 24 01 2C 03 2C 66"!let/IP界面类校正=4Object_Name=TCP/IP接口对象Object_Class_Code=0xF5MaxInst=1数表Satistic#Instances=1最大数_Of_Dynic_Instances=0Class_Attributes = 1, 2, 3, 4, 6, 7!Instance_Attributes = 1, 2, 3, 4, 5, 6, 8, 9, 10, 11, 13, 16, 17!services=0x01x0E实例_services=0x01,0x0E,0x10校正=4Object_Name=Ethernet链接对象Object_Class_Code=0xF6MaxInst=2数表静态=2最大数_Of_Dynic_Instances=0Class_Attributes = 1, 2, 3, 4, 6, 7!Instance_Attributes = 1, 2, 3, 6, 7, 8, 9, 10, 11, 12, 13, 14!services=0x01x0E实例_services=0x01,0x0E,0x10修订版=1Object_Name=识别对象Object_Class_Code=0x01MaxInst=1数表Satistic#Instances=1最大数_Of_Dynic_Instances=0类分配数=1、2、3、6、7Instance_Attributes = 1, 2, 3, 4, 5, 6, 7!services=0x01x0Eservices=0x010x050x0E修订版=1Object_Name=Message路由器对象Object_Class_Code=0x02MaxInst=1数表Satistic#Instances=1最大数_Of_Dynic_Instances=0Class_Attributes = 1, 2, 3, 4, 5, 6, 7!实例_属性=1,2,3services=0x01x0E实例_Services=0x10,0x0A